Filling, Topping Up Storage Tank - With Optional Kfe Filling Connection Or With Installed Drainback Solar System - Daikin EKHHP300A2V3 Manuel D'installation Et D'utilisation

Masquer les pouces Voir aussi pour EKHHP300A2V3:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.2.2 Filling, topping up storage tank - with optional
KFE filling connection or with installed
DrainBack solar system
● Without solar system: Connect KFE filling connection
(accessory KFE BA) to the filling and draining connection of
the DAIKIN EKHHP (see overview image on page 2, item 10)
or
With solar system: Mount KFE filling connection
(accessory KFE BA) on the connection bracket of the
control and pump unit (RPS3).
● Connect the filling hose with backflush prevention (1/2") to
the previously installed KFE cock.
● Fill the storage tank on the DAIKIN EKHHP until water
comes out of the connection (fig. 7-1, item 23), that has
been connected as the safety overflow.
● Disconnect the filling hose with backflush prevention (1/2")
again.
1
23
Fig. 7-1
Buffer storage filling - without solar system
DAIKIN EKHHP(3/5)00AA2V3
DAIKIN Hot water heat pump
008.1423444_02 – 09/2015
7
x
Service and maintenance
Installation and maintenance manual
33

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ekhhp500a2v3

Table des Matières