After having ignited the heater, always check whether the combustion
chamber ¿ is level, by sliding it slightly to the left and the right by its handle ´
(Fig. E). This should be a smooth movement. If the combustion chamber is not
level, this will cause smoke and soot to develop.
D
BURNING OF THE HEATER
After you have ignited the heater, it will take 10 to 15 minutes before you can check
whether the heater is burning well. Too high a flame may cause smoke and soot,
whereas too low a flame causes smells. The page opposite the folding page shows
the minimum and maximum permissible burning heights of the flame (Fig. R).
L
If the flame remains low after the adjustment, the wick height must be
adjusted (refer to Section F).
Burning that is too low may be caused by:
insufficient fuel
poor fuel quality
insufficient ventilation
wastage of the wick
When there is insufficient ventilation in the room, an intermittent buzzer will be
M
heard and the VENT lamp (Yellow) will be lit. When this signal is given, ensure that
the ventilation of the room is improved (e.g. by opening a door or window a little
more) to avoid that the heater shuts off. When the ventilation of the room is
improved, the VENT lamp and buzzer will be deactivated. When there is still insuf-
ficient ventilation, the heater shuts off automatically. After improving the ventila-
tion of the room (e.g. by opening a door or window a little more), the heater can
be ignited again.
This heater is fitted with a safety system that ensures that it switches off if you
lift the exchange tank out of the heater. To switch the heater on again, put the
N
exchange tank back and follow the steps in chapter C.
E
SWITCHING OFF THE HEATER
Push the OFF-button ³. The flame will extinguish after a little while.
F
ADJUSTING THE WICK HEIGHT (R21E)
After a period of time the combustion may no longer be high enough (Section D). In
O
that case you can adjust the wick height to improve the flame. To do this, the heater
must have been switched off. Follow the procedure below:
Push the OFF button ³ (Fig. N).
1
Pull the knurled wick adjustment knob · off the heater, so the wick height
2
lock ¸ will be visible.
Take the plastic collar between your thumb and index finger and pull it out.
3
Turn the collar up one step, to either position 2 or 3 (Fig. O). Carefully push
the collar back, so the pin engages in the recess.
(fill the tank)
(contact your dealer)
(put window or door ajar)
(contact your dealer or replace the wick,
refer to section M)