First-Aid Measures; Flue - Nordica ROSSELLA R1 BII Instructions Pour L'installation, L'utilisation Et L'entretien

Masquer les pouces Voir aussi pour ROSSELLA R1 BII:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ROSSELLA R1 BII – LUNA BII
c) If the product is installed on a non totally refractory floor, one must foresee a fireproof background. The floors
made of inflammable material, such as moquette, parquet or cork etc., must be replaced by a layer of no-
inflammable material, for instance ceramic, stone, glass or steel etc. (dimensions according to the regional law)).
In case the replacement of the floor is not possible, the appliance shall be placed on a minimum 12 cm
thick slab made of stone or concrete The platform must stick out 30 cm's sideways and 50 cm's on the front
side over the loading door (Picture 2 B)
d) no flammable components (e.g. wall units) must be present above the product.
The chimney stove must operate exclusively with the ash drawer inserted. The solid residue of the combustion
(ashes) must be collected in a hermetic container, resistant to fire. The stove must never be ignited when there are
gas or steam emissions (e.g. glue for linoleum, gasoline, etc.). Never deposit flammable materials near the stove.
During the combustion will be spread thermal energy which warms up the surfaces, the door, the fireplace glass, the
handles and knobs, the smoke pipe and the front side of the stove. Please avoid the contact of these parts without
gloves or the relevant tools.
Warn children of the danger and keep them away during the operation of the stove.
The use of a wrong or wet fuel causes the formation of creosote deposits in the flue and will fuel a chimney fire.
4.1.

FIRST-AID MEASURES

Should any fire arise in the stack or in the flue:
a) Close the feeding door and the ash drawer door;
b) Close the controls of combustion air;
c) Extinguish the fire using carbon dioxide fire-fighting means (CO
d) Seek immediate intervention of FIRE BRIGADE.
DO NOT EXTINGUISH FIRE USING WATER JETS.
When the fire has been extinguished, let the flue check by an expert to find possible cracks and permeable points.

5. FLUE

Essential requirements for a correct operation of the appliance:
the internal section must be preferably circular;
be thermally insulated and water-proof and produced with materials suitable to resist to heat, combustion
products and possible condensates;
not be throttled and show a vertical arrangement with deviations not greater than 45°;
if already used, it must be clean;
observe the technical data of the instructions manual;
Should the flues have a square or rectangular section, internal edges must be rounded with a radius not lower than 20
mm. For the rectangular section, the maximum ratio between the sides must be ≤ 1.5.
1191015 – EN
A
B
dust);
2
Picture 2
19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Luna bii

Table des Matières