Wash the face mask and the exhalation valve assembly manually in warm
4.
cleaning fluid (maximum 55° C).
Rinse the parts in clean water.
5.
Disinfect the face mask and the exhalation valve assembly. Follow the instructions
6.
supplied with the disinfectant.
Rinse the face mask and the exhalation valve assembly thoroughly with clean
7.
water.
Shake the mask to remove excess water and dry the mask and the exhalation
8.
valve assembly.
Lubricate the pin of the exhalation valve sparingly with silicone lubricant
9.
331900269.
Place the pin of the exhalation valve in the hole in the mask connector and mount
10.
the exhalation valve holder. [Fig. 12]
Place the face mask cover over the valve connection and push the locking tabs
11.
into the face mask connection piece.
BREATHING VALVE
Clean the outside of the breathing valve with a cloth and lukewarm water
1.
(maximum 40° C) with Spirorein or equivalent to remove dirt.
Wipe the breathing valve clean with a cloth and clean water.
2.
Dry the breathing valve
3.
ATTENTION! WHEN CLEANING THE BREATHING VALVE IT MUST BE COMPLETELY DRY BEFORE IT IS
REASSEMBLED AND PUT BACK INTO SERVICE. REMAINING WATER MIGHT FORM ICE ON VITAL PARTS, RESULTING
IN MALFUNCTION OF THE BREATHING VALVE.
EXTENDED CLEANING
In certain circumstances it is necessary to clean the breathing valve on the inside.
Unscrew the cover of the breathing valve and remove the positive pressure spring.
1.
[Fig. 13]
Unscrew the locking nut of the breathing valve, use a spanner wrench (tool #
2.
95992-01) if necessary.
Remove the valve insert [Fig. 14], connect a breathing hose to pull out the valve
3.
insert if necessary.
Clean all parts except the valve insert in warm cleaning fluid (maximum 55° C).
4.
Rinse cleaned parts in clean water.
5.
Disinfect the valve housing including diaphragm. Disinfect the lever arm of the
6.
valve insert. Follow the instructions supplied with the disinfectant.
Rinse the disinfected parts.
7.
ATTENTION! WHEN DISINFECTING AND RINSING THE LEVER ARM ON THE VALVE INSERT NO WATER OR
FLUID MAY ACCESS THE VALVE INSERT. DO NOT DIP THE LEVER ARM DEEPER THAN THE WHITE RUBBER CAP.
8