Service And Adjustments; Accessories; Service Information - DeWalt DXCMLA1983054 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Air compressor Head Bolts - Torquing
The air compressor pump head bolts should be kept properly
torqued. Check the torques of the head bolts after the first five
hours of operation. Torque to 14-16 ft.-lbs. (18.9–21.7 Nm).

Service and Adjustments

ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED
MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN.
Risk of unsafe operation. Unit cycles automati-
cally when power is on. When servicing, you may be exposed
to voltage sources, compressed air, or moving parts. Before
servicing unit unplug or disconnect electrical supply to the air
compressor, bleed tank of pressure, and allow the air compres-
sor to cool.
To Replace or Clean Check Valve
Release all air pressure from air tank. See Draining Air Tank in
1.
the Maintenance section.
2.
Set the Auto/Off lever to "Off", unplug the unit, and relieve all
air pressure from the air tank.
3.
Using an adjustable
wrench loosen outlet
tube nut at air tank
and pump. Carefully
move
outlet
tube
away
from
check
valve.
nothing is
4.
Using an adjustable
wrench loosen pres-
sure relief tube nut
at air tank. Carefully
Screwdriver
In open
position
visible.
In closed position
disc is visible.
move pressure relief tube away from check valve.
5.
Unscrew the check valve (turn counterclockwise) using a 7/8"
open end wrench. NOTE the orientation for reassembly.
6.
Using a screwdriver, carefully push the valve disc up and
down. NOTE: The valve disc should move freely up and down
on a spring which holds the valve disc in the closed position, if
not the check valve needs to be cleaned or replaced.
7.
Clean or replace the check valve. A solvent, such as paint or
varnish remover can be used to clean the check valve.
8.
Apply sealant to the check valve threads. Reinstall the check
valve (turn clockwise).
9.
Replace the pressure release tube. Tighten nuts.
10. Replace the outlet tube and tighten nuts.
11. Perform the Break-in Procedure. See Break-in Procedure in
the Operation section.
Additional Service
Disassembly or service of the air compressor beyond what is cov-
ered in this manual is not recommended. If additional service is
required, contact your nearest Authorized Warranty Service Center.

Accessories

Recommended accessories for use with your tool are available for
purchase from your local dealer or authorized service center. If you
need assistance in locating any accessory for your tool, please call
1-888-895-4549 or visit our website www.dewalt.com.
WARNING: The use of any other accessory not recommended
for use with this tool could be hazardous. Use only accessories
rated equal to or higher than the rating of the air compressor.

Service Information

Please have the following information available for all service calls:
20

Publicité

Table des Matières
loading