Les langues disponibles

ASPIRAT FAULTY
FUMES PROBE
ALARM
FUMES OVERHEATING
CLEAN CHECK UP 1 2
1 = IN START UP STAGE
2= IN OPERATING STAGE
DEPR ALARM
NO
IGNITION
BLACK OUT NO IGN.
NO PELLETS
COOLING STAND BY
DEBIMETER
FAULT
AUGER CONTROL
ALARM
AUGER BLOCK
Indicates the presence of an alarm.
Fault correlated to the ue gas
exhaust motor.
Fault correlated to the fumes probe.
The ue gas temperature has
exceeded 310°C
The combustion chamber or burn pot
bottom are dirty.
The door is not closed correctly.
The ash drawer is not closed
correctly.
The depression sensor is faulty.
The ue exhaust pipe is blocked.
Incorrect installation
The mechanical depression sensor
has tripped
The pellet feed-box is empty.
Pellet feed calibration inadequate.
Incorrect installation
No current during the ignition phase.
In the work phase, the t° of the ue
gases has dropped below default
parameters
Attempt to release the alarm with
stove still in cooling mode.
Component disconnected or faulty
Anomalous functioning
of pellet feeding
Abnormal functioning
of pellet motor
On: indicates the presence of an alarm
O : indicates the absence of alarms
Flashing: indicates the deactivation of the depression sensor.
The alarm can be reset by pressing button 1 for 3 seconds only if
the fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
The restoration operations must be carried out by an authorised
technician.
The restoration operations must be carried out by an authorised
technician.
Check pellet ow (see "Pellet feed adjustment").
Check that the machine is clean, including the fumes passage.
Do not rest cloths on the machine.
Other restoration operations must be carried out by an authorised
technician.
Make sure the holes at the burn pot bottom are completely free.
Check cleanliness of the fumes pipe and the combustion chamber.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Other restoration operations must be carried out by an authorised
technician.
Contact after-sales centre
Check for the presence of pellets in the feed-box.
Adjust pellet ow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
Set the stove on OFF using key 1 and repeat the procedure
described in the "Ignition" chapter.
Other restoration operations must be carried out by an authorised
technician.
Check for the presence of pellets in the feed-box.
Regulate the pellet ow.
Other restoration operations must be carried out by an authorised
technician.
Every time the stove displays one of the alarms listed above it will
switch-o automatically.
The stove will block any alarm unlock attempt during this phase,
showing the alarm itself and STAND BY alternately on the display.
The alarm can be reset by pressing button 1 for 3 seconds only if
the fumes motor has stopped and if 15 minutes have elapsed from
when the alarm was displayed.
Contact after-sales assistance
Contact after-sales assistance
Contact after-sales assistance