GI701S
GIIA-4030-US/2OSSD/V4A
Response time when approaching
the enable zone (enable time)
Risk time (response time for safety
-related faults)
Environment
Applications
Ambient temperature
Rate of temperature change
Max. relative air humidity
Air pressure
Height above sea level
Ionising radiation
Salt spray
Protection
Tests / approvals
EMC
Shock resistance
Vibration resistance
Safety classification
Mission time TM
Safety-related reliability PFH
Mechanical data
Mounting
Housing materials
Weight
Displays / operating elements
Display
Electrical connection
Connection
Wiring
16
[ms]
[ms]
[°C]
[K/min]
[%]
[kPa]
[m]
IEC 60947-5-2
IEC 60947-5-3
EN 61000-4-2 ESD:
EN 61000-4-3 HF radiated:
EN 61000-4-4 Burst:
EN 61000-4-6 HF conducted:
EN 61000-4-8:
EN 55011:
[h]
[1/h]
D
[kg]
≤ 200
≤ 100
Class C to EN 60654-1 weatherproof application
-25...70, for service life ≤ 87600 h
10...40, for service life ≤ 175200 h
0.5
5...95, briefly
5...70, permanently
80...106
≤ 2000
not permissible
IP 68 / IP 69K
IEC 60947-5-2
IEC 60947-5-2
≤ 175200, (20 years)
1E-08
non-flush mountable
stainless steel 316L / 1.4404; PBT
0.255
LED yellow (signal), LED green (power)
M12 connector; Gold-plated contacts
1: Safety-related logic unit
no
Criteria: functional Safety (FS)
6 kV CD / 8 kV AD
20 V/m
2 kV
10 V
30 A/m
class B