Insert And Level Throat Plate; Anti-Kickback Pawls And Blade Guard - ShopMaster DELTA S36-300 Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.
Return the riving knife lock lever to the lock position.
5.
Make sure the riving knife is securely installed and
properly aligned with the blade.
NOTE: For "non-thru cuts", lower the riving knife to the
"non-thru cut" position using the same procedure. In this
case the "non-thru cut" position line should be parallel to
and level with the table.
INSERT AND LEVEL THROAT
PLATE
Insert the rear tab of the throat plate (the end with the wear
plates) under the surface of the table, and snap the front
end in place (Fig. 13).
Check that the throat plate is properly adjusted to the
table. Front of throat plate should be level or slightly below
the surface of the table and rear of the throat plate should
be level or slightly above the surface of the table (Fig. 13).
If adjustment is needed, remove the throat plate and
adjust the (4) Phillips set screws (Fig. 14) up or down as
needed. Replace throat plate and recheck. Repeat this
process as needed until the throat plate is level.
It is important that the throat plate is
properly adjusted to the table. This ensures that the work
piece is not caught on the throat plate or the table when
feeding the work piece through the blade during a cut.
ANTI-KICKBACK PAWLS
AND BLADE GUARD
Riving knife (E) must be in the through cut position prior
to installation of the anti-kickback pawls (D) and blade
guard (F)
Insert the pawl assembly (D) into the middle slot on the
riving knife (E) as shown in Fig. 15 while pressing the
spring-loaded pin on the right side of the pawl assembly.
Once inserted, release the spring-loaded pin so that it
pops back in to place (Fig. 15). Ensure that it is locked in
place.
ASSEMBLY
D
14
WEAR
PLATE
FIGURE 13
FIGURE 14
PIN
E
FIGURE 15