EN
> leARnIng The TRAvel oF The gATe - CTR50
Indicator
S4
lED Dl1
1 2 3 4 5 6 7 8 9 10
ON
OFF
8 9 10
11
12
13
14
15
16
17
18
19
Manually position the gate in its fully open
J2
position (Figure 1).
Use the manual unlocking system or a 12V
1
battery to put the motors in position.
NB: mandatory central and side stops
(non supplied)
Press P2 during 2 seconds (on the electrical
portection's cover. the motors open during
1 second
2
the gate. After 5 seconds, the motor M2 starts
closing
(Figure 2)
Wait for the leaves to be completely closed and
check that each motor stops on the central
3
limit stop, after 2 seconds of thrust. (Figure 3)
In case of error :
If at step 2, the motors start closing (to 30 cm), stopping, then openning : invert the motor's polarities
(invert the MoT 1 wire and MoT 2 wire).
en ::: 28
DL1
P1
P2
P3
RV1
20
21 22 23 24 25 26 27 28
J3
then the motor M1 starts closing
1
.
2
Keys P1, P2 and P3
Potentiometer RV1
Mandatory
side stop
Mandatory
side stop
MOt 1
during gate travel learning,
all safety devices are
ignored.
Take all necessary
precautions and keep
everyone away from the
installation.
Mandatory
central stop
FIguRe 1
1
1
MOt 2
after
s
2
MOt 1
MOt 2
FIguRe 2
FIguRe 3
Mandatory
side stop
Mandatory
side stop
1
after
s
after 5s