> leARnIng The AuToMATIC TRAvel oF The gATe - CTR52
CODES
Indicator
DL1
lED Dl1
P1
RV1
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Manually position the gate in its fully open position
against the limit stops (Figure 1).
Use the manual unlocking system or a 24V battery
to put the motors in position.
1
NB: mandatory central and side stops
(not supplied)
Press P2 for 2 seconds, motor 1 starts closing the
gate. Wait for 3 seconds then press P2 again, motor
2 starts closing the gate.
2
If the travel is not complete (the gate stops before
the central limit stop), increase potentiometer RV1.
Wait for the leaves to be completely closed and
check that each motor stops on the central limit
3
stop after 2 seconds of thrust. (Figure 3)
If > 2 seconds, reduce Rv1 slightly
en ::: 27
TIME
PAUSE
Keys P1, P2 and P3
P2
P3
R5
R6
Potentiometer RV1
RL5
RL1
RL2
RL3
C1
RL4
PD1
FS2
FS1
FS3
~24Vac~
Mandatory
side stop
MOt 1
during gate travel learning,
all safety devices are
R13
ignored.
24V
Take all necessary
precautions and keep
12V
everyone away from the
F1
installation.
Position the potentiometer
Rv1 to 3/4 of its travel
FS4
+BATT-
Mandatory
central stop
FIguRe 1
MOt 2
FIguRe 3
EN
Mandatory
side stop
after 3s