TECHNICAL DATA
Production code .........................................................................................
Rated input ..............................................................................
Output ......................................................................................
No-load speed .........................................................................
Speed under load max. ...........................................................
Rate of percussion under load max .........................................
Static jamming moment*, 1st gear...........................................
Drilling capacity in concrete .....................................................
Drilling capacity in brick and tile ..............................................
Drilling capacity in steel ...........................................................
Drilling capacity in wood ..........................................................
Drill opening range ..................................................................
Drive shank..............................................................................
Chuck neck diameter ...............................................................
Weight according EPTA-Procedure 01/2003 ...........................................
* Measured according to Milwaukee norm N 877318
Noise information
Measured values determined according to EN 60 745.
Typically, the A-weighted noise levels of the tool are:
Sound pressure level (Uncertainty K=3dB(A)) ...........................
Sound power level (Uncertainty K=3dB(A)) ...............................
Wear ear protectors!
Vibration information
Total vibration values (vector sum in the three axes)
determined according to EN 60745.
Vibration emission value a
:
h
Drilling into metal .....................................................................
Uncertainty K ...........................................................................
Percussion drilling into concrete ..............................................
Uncertainty K ...........................................................................
WARNING
The vibration emission level given in this information sheet has been measured in accordance with a standardised test given
in EN 60745 and may be used to compare one tool with another. It may be used for a preliminary assessment of exposure.
The declared vibration emission level represents the main applications of the tool. However if the tool is used for different
applications, with different accessories or poorly maintained, the vibration emission may differ. This may signifi cantly increase
the exposure level over the total working period.
An estimation of the level of exposure to vibration should also take into account the times when the tool is switched off or
when it is running but not actually doing the job. This may signifi cantly reduce the exposure level over the total working period.
Identify additional safety measures to protect the operator from the effects of vibration such as: maintain the tool and the
accessories, keep the hands warm, organisation of work patterns.
WARNING! Read all safety warnings and all instructions.
Failure to follow the warnings and instructions may result in electric
shock, fi re and/or serious injury.
Save all warnings and instructions for future reference.
DRILL / PERCUSSION DRILL SAFETY WARNINGS
Wear ear protectors when impact drilling. Exposure to noise can
cause hearing loss.
Use auxiliary handle(s), if supplied with the tool. Loss of control
can cause personal injury.
Hold the power tool by insulated gripping surfaces only, when
performing an operation where the cutting accessory may
contact hidden wiring or its own cord. Cutting accessory
contacting a "live" wire may make exposed metal parts of the power
tool "live" and could give the operator an electric shock.
SCREWDRIVER SAFETY WARNINGS
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory may
contact hidden wiring or its own cord. Fasteners contacting a "live"
wire may make exposed metal parts of the power tool "live" and could
give the operator an electric shock.
20
ENGLISH
DE 10 RX
PDE 13 RX
........................... 4152 75 01... ................... 4152 76 01...
...000001-999999
...000001-999999
...............................630 W .................................. 630 W
...............................315 W .................................. 315 W
......................... 0-2700 min
........................0-2900 min
-1
-1
......................... 0-1500 min
........................0-1500 min
-1
-1
....................................- .................................22500 min
-1
.................................21 Nm ................................. 21 Nm
....................................- ....................................... 15 mm
....................................- ....................................... 18 mm
.................................10 mm ................................. 13 mm
.................................30 mm ................................. 30 mm
...........................1,5-10 mm ...........................1,5-13 mm
.........................1/2"x20 ...............................1/2"x20
.................................43 mm ................................. 43 mm
................................1,6 kg .................................. 1,8 kg
.................................84 dB (A) ........................... 100 dB (A)
.................................95 dB (A) ............................111 dB (A)
................................3,5 m/s
2
............................... 3,5 m/s
2
................................1,5 m/s
2
............................... 2,8 m/s
2
....................................- ....................................... 26 m/s
2
....................................- ...................................... 1,5 m/s
2
ADDITIONAL SAFETY AND WORKING INSTRUCTIONS
Use protective equipment. Always wear safety glasses when working
with the machine. The use of protective clothing is recommended,
such as dust mask, protective gloves, sturdy non-slip footwear, helmet
and ear defenders.
The dust produced when using this tool may be harmful to health. Do
not inhale the dust. Wear a suitable dust protection mask.
Do not machine any materials that present a danger to health (e.g.
asbestos).
Switch the device off immediately if the insertion tool stalls! Do not
switch the device on again while the insertion tool is stalled, as doing
so could trigger a sudden recoil with a high reactive force. Determine
why the insertion tool stalled and rectify this, paying heed to the safety
instructions.
The possible causes may be:
• it is tilted in the workpiece to be machined
• it has pierced through the material to be machined
• the power tool is overloaded
Do not reach into the machine while it is running.
The insertion tool may become hot during use.
WARNING! Danger of burns
• when changing tools
• when setting the device down
Chips and splinters must not be removed while the machine is
running.
Keep mains lead clear from working range of the machine. Always
lead the cable away behind you.
When working in walls ceiling, or fl oor, take care to avoid electric
cables and gas or waterpipes.
Clamp your workpiece with a clamping device. Unclamped
workpieces can cause severe injury and damage.
Always disconnect the plug from the socket before carrying out any
work on the machine.
When working with large drill diameters, the auxiliary handle must be
fastened in a right angle with the main handle (see illustrations,
section "Twisting the handle").
SPECIFIED CONDITIONS OF USE
DE 10 RX: The drill can be used for drilling in wood, metal and
plastics and for screwdriving.
PDE 13 RX:
The electronic drill/screwdriver can be universally
used for drilling, percussion drilling, screwdriving and cutting
screw threads.
Do not use this product in any other way as stated for
normal use.
EC-DECLARATION OF CONFORMITY
We declare under our sole responsibility that the product described
under "Technical Data" fulfi lls all the relevant provisions of the
directives 2011/65/EU (RoHs), 2004/108/EC (until 19 April 2016),
2014/30/EU (from 20 April 2016), 2006/42/EC and the following
harmonized standards have been used:
EN 60745-1:2009 + A11:2010
EN 60745-2-1:2010
EN 60745-2-2:2010
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:1997 + A1:2001 + A2:2008
EN 61000-3-2:2014
EN 61000-3-3:2013
EN 50581:2012
Winnenden, 2016-02-02
Alexander Krug
Managing Director
Authorized to compile the technical fi le
Techtronic Industries GmbH
Max-Eyth-Straße 10
71364 Winnenden
Germany
MAINS CONNECTION
Appliances used at many different locations including wet room and
open air must be connected via a residual current device (FI, RCD,
PRCD) of 30mA or less.
Connect only to single-phase AC current and only to the system
voltage indicated on the rating plate. It is also possible to connect to
sockets without an earthing contact as the design conforms to safety
class II.
Make sure the machine is switched off before plugging in.
MAINTENANCE
The ventilation slots of the machine must be kept clear at all times.
If the machine is mainly used for percussion drilling, regularly remove
collected dust from the chuck. To remove the dust hold the machine
with the chuck facing down vertically, and completely open and close
the chuck. The collected dust will fall from the chuck.
It is recommended to regularly use cleaner for the clamping jaws and
the clamping jaw borings.
If the supply cord of this appliance is damaged, it must only be
replaced by a repair shop appointed by the manufacturer, to avoid
hazardous situations
Use only Milwaukee accessories and spare parts. Should
components need to be replaced which have not been described,
please contact one of our Milwaukee service agents (see our list of
guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please state
the Article No. as well as the machine type printed on the label and
order the drawing at your local service agents or directly at: Techtronic
Industries GmbH, Max-Eyth-Straße 10, 71364 Winnenden, Germany.
SYMBOLS
CAUTION! WARNING! DANGER!
Always disconnect the plug from the socket before
carrying out any work on the machine.
Please read the instructions carefully before starting
the machine.
Accessory - Not included in standard equipment,
available as an accessory.
Do not dispose of electric tools together with
household waste material.
Electric tools and electronic equipment that have
reached the end of their life must be collected
separately and returned to an environmentally
compatible recycling facility.
Check with your local authority or retailer for recycling
advice and collection point.
Class II tool, tool in which protection against electric
shock does not rely on basic insulation only, but in
which additional safety precautions, such as double
insulation or reinforced insulation, are provided.
There being no provision for protective earthing or
reliance upon installation conditions.
European Conformity Mark
Regulatory Compliance Mark (RCM). Product meets
applicable regulatory requirements.
National mark of conformity Ukraine
EurAsian Conformity Mark.
ENGLISH
21

Publicité

loading

Ce manuel est également adapté pour:

Pde 13 rx