In this paragraph all configuration parameters are described making reference to the configuration
interface from PC. However the same interface with the same lay-out is available using the APP, the
Ksenia SecureWeb or locally by means of the WebServer.
In this section it's possible to configure the Partitions Descriptions and the 2 programmable arming
modes. Furthermore it is possible to configure the activation modalities of the Partitions related to the
2 programmable arming modes.
NOTE: the Disarm and Full Arm modes can not be modified.
EN
In this section you can configure up to 8 IP Cameras which will be activated in case of Alarm to en-
able screen-shots to be sent to the programmed recipients as email enclosures and/or Push Notifica-
tion.
Here you can configure all parameters associated to the mother board. It's divided in 3 sub-sections:
1. Inputs
It's possible to configure the Panel inputs (i1, i2, i3, i4) to which the wired sensors have to be linked.
The programmable Parameters for each input are the following:
Description: name associated to the input.
Partition: to which the sensors are associated. The factory default data are associating them to the first
partition (Doors and Windows).
Camera: is the camera associated to the Sensor, active in case of Alarm.
Input type: according to the linked Sensor, the way of processing the signal can be set-up as follows:
• Non Used: deactivated input
• Normally Closed: for an input linked to a normally closed type of Peripheral (e.g. Magnetic Contact,
not balanced Motion Detector, etc)
• Normally Open: for an input linked to a normally open Peripheral (e.g. Pushbutton)
• Double Balance: for inputs linked to a Peripheral with EOL resistors both on Alarm and tamper.
The Double Balance will be achieved using 10K Ohm Resistors in parallel or 4,7K in series.
• Low sensitivity Roller Blind: for input linked to Shutter Detector. Low Sensitivity in detection.
(7 pulses in 180 seconds).
• High sensitivity Roller Blind: for input linked to Shutter Detector. High Sensitivity detection.
(4 pulses in 180 seconds).
• Low sensitivity Inertial: for input linked to Break Detector. Low Sensitivity in detection.
(7 pulses in 30 seconds).
• High sensitivity Inertial: for input linked to Break Detector: High Sensitivity in detection.
(4 pulses in 30 seconds).
Delayed: enable this zone if you want this Sensor not to generate Alarms during the Entrance and Exit
Time.
Auto-bypassable: the Sensor will be automatically bypassed if during arming results violated. The Sen-
sor bypassing during the arming phase is totally transparent to the User and there will be no notifica-
tion to the Panel whatsoever, but it will be registered on the Event Log.
The auto-bypass function does not exclude any tamper.
The Sensor is automatically re-included by the next disarming.
Chime: if this option will be selected, when the Sensor is violated with Partitions armed, it generates a
voice message on the local Keypad (or remote if the KP is linked to the BUS) with Sensor Identification.
If the voice option is disabled, then it generates bips of 5 seconds each.
Always Activate: if this option will be selected, when the Sensor is violated an Alarm will be generated
regardless the arming of the relevant Partition.
44
CONFIGURATION MENU (PC, MAC or APP)
PARTITIONS
CAMERAS
MOTHER BOARD

Publicité

Table des Matières
loading

Table des Matières