Connection With The Mains; Operation; Stand Alone Operation - EuroLite TS-10 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.

Connection with the mains

Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection-cables is as follows:
Cable
Pin
Brown
Live
Blue
Neutral
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the effect to the mains, the TS-10 starts running. During the Reset, the motors are
trimmed and the device is ready for use afterwards.
Turn the objective-lens for adjusting the focus in order to obtain a sharp projection.

Stand Alone operation

In the Stand Alone mode, the TS-10 can be used without controller. Disconnect the TS-10 from the controller
and call the internal program.
Please refer to the instructions under Control Board.
International
L
N
26/57
resistor
00031630.DOC, Version 1.0

Publicité

Table des Matières
loading