Master/Slave-Operation; Dmx-512 Connection / Connection Between Fixtures - EuroLite TS-5 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Pull the safety bond through the attachment eyelet and over the trussing system or a safe fixation spot.
Insert the end in the quick link and tighten the safety screw.
The maximum drop distance must never exceed 20 cm.
A safety bond which already held the strain of a crash or which is defective must not be used again.
Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!

Master/Slave-operation

The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the TS-5 you can find an XLR-jack (DMX Out) and an XLR-plug (DMX In), which can be
used for connecting several devices.
Choose the device which is to control the effects. This device then works as master-device and controls all
other slave-devices, which are to be connected to the master-device via a balanced microphone lead.
Connect the DMX OUT-jack with the DMX IN-plug of the next device.
Set the Master-mode for the master-device (F4 – yes). You can connect as many slave-devices as you like.

DMX-512 connection / connection between fixtures

The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
25/57
00026361.DOC, Version 1.3