2. Icons and symbols

Icons and symbols are used in these operating instructions to make it easier to understand and
use them.
Symbol
Meaning
This symbol highlights useful and important product information.
>
Action required
Do not dispose of in household waste
Long signal tone
Short signal tone
s
Seconds
S1
Service programme 1: 5-minute flush stop
S2
Service programme 2: Intermittent flushing
S3
Service programme 3: System check
S4
Service programme 4: Flushing duration
S5
Service programme 5: Reset
P1
Flushing programme 1: 0.5 litres
P2
Flushing programme 2: Standard
P3
Flushing programme 3: Vario

3. Product description

3.1 Design

Refer to page 3 for a diagram showing the urinal.
1 Magnetic key
2 Solenoid valve
3 Sensor for magnetic key

4 Control unit

5 Shut-off valve with dirt filter
6 6V lithium battery or power supply
3.2 Control unit
The electronic urinal control unit enables touch-free flushing. The electronics for this
operate by using automatic infra-red leg detection. If the urinal has been used for at least
9  seconds, then the flush will automatically be triggered once the user moves away from
the urinal. People walking past or objects continuously left in the control unit's range do not
trigger flushing. Automatic flushing every 12  hours maintains hygiene and prevents the
build-up of unpleasant odours.