12
Rear Ducted Installation for 1 motor Rangehood
The Electrical Connector must be
removed first before converting the
hood to Rear Ducting mode.
Disconnect the Electrical Connector
by depressing the tabs with your
hand and also using light force on
one tab with a flat head screwdriver.
For a rear ducting installation the
motor needs to be unsecured by first
removing the 12 screws as shown.
Once the screws are removed,
extract the blower from the body
of the Hood and position it so the
transition opening is facing to the
rear wall (from the back remove and
rotate 180 degrees to the left, and
then flip it back 90 degrees as shown
in the diagram).
Once the blower is in place re-install
the 12 screws to fasten the motor to
the Hood body.
Reconnect the Connector to the
blower.