3.2.3. Connections
Connect the wind vane-gauge sensor to the LT8 connector
Connect the - power to the black wire without connector and the red
wire to the + power via a switch and a 1A fuse.
For a system comprising several "Advansea" instruments, connect all the
orange bus wires from each instrument together.
Connect an NMEA source (GPS for example) to the yellow wire for the
+nmea and the black for the – nmea
See diagram below: