Change pump oil after the first 50 hours of operation and every 300
hours thereafter.
to cHeck oIL
The oil level should come to the dot in the middle of the sight
glass (AA).
HoW to cHanGe
PuMP oIL
1. Loosen pump dipstick/oil
plug (BB).
2. Place a container under
the oil drain plug (CC).
3. Remove pump oil drain
plug.
4. After oil is drained, replace
oil drain plug. Tighten securely.
Remove pump dipstick/oil plug and fill with 30W non-detergent oil.
5.
6. Replace pump dipstick/oil plug and tighten securely.
Nozzle Cleaning
If the nozzle becomes clogged with foreign materials, such as dirt,
excessive pressure may develop. If the nozzle becomes partially
clogged or restricted, the pump pressure will pulsate. Clean the
nozzle immediately using the nozzle kit supplied and the following
instructions:
1. Shut off the pressure washer and turn off the water supply.
2. Pull trigger on gun handle to relieve any water pressure.
3. Disconnect the spray wand from the gun.
4. Remove the high-pressure nozzle from the
spray wand. Remove any obstructions with
the nozzle cleaning tool (Y) provided and
back flush with clean water.
BB
AA
CC
Y
5. Direct water supply into spray wand to
back flush loosened particles for 30
seconds.
6. Reassemble the nozzle to the wand.
7. Reconnect spray wand to gun then turn on water supply.
8. Start pressure washer and place spray wand into high pressure
setting to test.
To Clean the Water Inlet Filter
This filter screen (U) should be checked periodically and cleaned if
necessary.
1. Remove the filter screen (U) by grasping the
end and removing it from water inlet of pump.
2. Clean filter by flushing it with water on both
sides.
3. Reinsert filter into water inlet of pump. Cone
side faces out.
note: Do not operate pressure washer without
filter properly installed.
StoraGe
Engine
Consult the engine instruction manual for the man u fac tur er's
recommendations for storage.
Pump
The
manufacturer
recommends
winterizer when storing the unit for more than 30 days and/or
when freezing temperatures are expected. If a pump protector/
winterizer is not available, RV antifreeze can be used as outlined in the
following steps.