To bring the roller into contact with the tube, loosen the clamping wheel of the tool-holding plate and push
the head until the roller touches the tube. Then continue to push for approximately 5 mm to pre-stress the
spring on the inside of the head.
To adjust the distance between the tube and the electrode, turn the adjustment nut.
Join
experience
0
SAS au capital de 135 720 € - RCS Romans B414 581 363 – Code APE 2841 Z – Siret 414 581 363 00028 – TVA FR13414 581 363
Tool-holding plate
clamping wheel
Indexing lever at
weld position
Indexing allows the tube to
be
released
displacing the machine.
Roller at a tangent to the tube +
pre-stressed spring
Sliding