Error messages

In case of any defects, an error message appears on the display. Follow the directions supplied or contact an authorized dealer.
Fault
Error message
Code
F01
MOTOR OVERHEATED
F02
POWER PACK OVERHEATED
F03
LOW VOLTAGE
F04
HIGH VOLTAGE
F05
OVER CURRENT
F06
NO HALLSENSOR LENGTH
F07
NO HALLSENSOR ARM
F08
TRAVEL MOTOR OVERLOADED
F09
DEPTH MOTOR OVERLOADED
F10
BLADE JAM
F11
GROUND FAULT OR NO SAW HEAD
F12
NON-COMPATIBLE SAW UNIT
F13
NO CONTACT CHECK CAN-CABLE
F14
NO RADIO CONTACT
MAINTENANCE
Procedure
Water coolant lacking/
insufficient to saw motor.
Water coolant lacking/
insufficient to power pack.
Low voltage supply to the
power pack.
High voltage supply to the
power pack.
Over current to saw motor
Fault on HALL-sensor card for
travel feed
Fault on HALL-sensor card for
depth feeding
Travel motor overloaded.
Depth motor overloaded.
Blade can not rotate.
Incorrect earthing of power
pack/saw or no saw unit
connected to the power pack.
Incorrect saw unit connected
to the power pack.
No contact between power
pack and remote control
No radio contact between
remote control and power
pack.
Steps
Check that the water coolant flows to the saw
motor and that it is max. 25ºC and min 3.5 l/
min.
Check that the water coolant flows to the
power pack and that it is max 25°C and min
3.5 l/min. If the message pops up when the
blade rotation is started - go to the operations
menu and "Water coolant" and select "ON".
Let the water coolant circulate the power pack
for a minute before you turn the blade rotation
on again.
Check the voltage during operation. Check
that all three phases exist. Check that
incoming cables have sufficient cross-
sectional area.
Check the voltage during operation. This
message is shown mainly when using a
generator as power source.
Check that the power lead is fitted correctly
and that it is not damaged. The message can
appear in case of a loose contact.
Take the equipment to an authorized service
shop.
Take the equipment to an authorized service
shop.
To reset, reverse the feeding function. If the
fault message returns, grease the feeder
gears, clean the rails and adjust the saw
carriage. If this does not help, hand in the
equipment to an authorized Husqvarna
service workshop.
To reset, reverse the feeding function. If the
fault message returns, grease the feeder
gears. If this does not help, hand in the
equipment to an authorized Husqvarna
service workshop.
Remove the blade from the cut and start the
blade rotation.
Check the incoming electrical connection to
the power pack and that the saw unit is
connected to the power pack. If this does not
help, hand in the equipment to an authorized
Husqvarna service workshop.
Connect a compatible saw unit to the power
pack.
Replace the CAN-cable.
Check that the power pack is activated and
that the green indicator light is on. If this does
not help, hand in the equipment to a
Husqvarna service workshop. The machine
can be used with the CAN cable between the
power pack and remote control.