CAUTION
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Filling water when it is in the low water level.
11. This appliance is not intended for use by persons (including children) with
12. Children should be supervised to ensure that they do not play with the appli-
TROUBLESHOOTING
Problem
No air flow
Fail to shutdown the Fan
Abnormal sound from
Product body
No damping
Air flow direction can not
be controlled
4
48
Use normal power supply.
Do not place objects on the top of the unit. Do not cover the air outlet when
in use and obstructed of front and back in one meter.
After filling with water, do not tilt or collide the unit, when you need to
move the unit, push the side surface slowly so as to avoid water splashing
out. Do not overturn the unit in service to prevent accident (F.4).
The body of the unit may not be place in area with extremely high or low
temperature. In hot summer, the water in its water tank is liable to deterio-
ration with odor and should be changed frequently. In winter, at room tem-
perature lower than 0 degree, it is necessary to remove the water and clean
with dry towel to avoid frost.
In cleaning the outer surface of the unit, wet cloth (or with some detergent)
should be used. Do not use any corrosive cleaner or solvent for this purpose.
Rinsing with water is absolutely not allowed. (F.5)
If packed for storage or transportation, please drain the water and make the
unit working a few minutes, after totally dry then pack it, in order to avoid
the peculiar smell.
Don't keep the plug connecting when long time no using the unit, it will be
damaged.
If the supply cord is damaged, it must be replaced by the manufacture or its
service agent or a similarly qualified person in order to avoid a hazard.
The unit has strong humidity effect, please shut this function in the airtight
environment.
reduced physical, sensory or mental capabilities or lack of experience and
knowledge, unless they have been given supervision or instruction concer-
ning se of the appliance by a person responsible for their safety.
ance.
Cause
1. Power is not connected.
2. Power is not turned ON.
3. Body damaged.
1. Stop key has not been pressed
yet.
2. Body damaged.
1. Foreign article inside the body.
2. Loose air wheel.
3. Motor defect.
1. Defective pump or motor.
1. Defective front synchronization
motor.
Solution
1. Plug the power cable properly.
2. Press the power key to start.
3. Return to Service Center.
1. Press key Start/Stop.
2. Return to Service Center.
1. Remove rear cover and strainer,
remove foreign articles.
2. Return to Service Center.
3. Return to Service Center.
1. Return to Service Center.
1. Return to Service Center.