Performance Data Sheet - Omnifilter OM34K Instructions D'installation

Adoucisseur d'eau
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PERFORMANCE DATA SHEET

Model
Rated Service Flow (gpm)
Pressure Drop at Rated
Service Flow Rate (psid)
Rated Capacity
(grains @ lb of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum Flow Rate During
Regeneration (gpm)
Indion 225 NaF
Ion Exchange Resin (cu ft)
Tank size
Backwash - GPM
Rapid Rinse/purge - GPM
Operating Pressure: 20 -125 psi or 1 .4 – 8 .8 kg/Centimeter
Acceptable Salt Type: Sodium Chloride – Pellet salt
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5,
Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific
performance claims as verified and substantiated by test data. The rated salt efficiencies above were
also determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above.
An efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies
with specific performance specifications intended to minimize the amount of regenerant brine and water
used in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not less that
3350 grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of
total hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating. The
rated efficiency of the water softener, the salt dosage at that efficiency, the capacity at that salt dosage
and that of the efficiency is only valid at the stated salt dosage. Efficiency is measured by a laboratory
test described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can
achieve. Operational efficiency is the actual efficiency achieved after the system has been installed. It
is typically less than the efficiency due to individual application factors including water hardness, water
usage, and other contaminants that reduce the water softener's capacity. These systems are not intended
to be used for treating water that is microbiologically unsafe or of unknown quality without adequate
disinfection before or after the system. Refer to the system Installation and Service Manuals for set-up
and programming instructions.Contact your local OMNI FILTER dealer for parts and service. See your
owners manual for warranty information .
Important Notice: For conditions of use, health claims certified by the California Department of Public
Health and replacement parts, see product data sheet
Iowa Requirement:
Seller: ________________________________________________ Date: _________________________
Buyer: ________________________________________________ Date: _________________________
9/21/11
20 • OC11 OM34K and OM40K
OM34K
9 .6
15 .0
15,095 @ 3.4
34,433 @ 16.7
4,396/lb Salt @ 3.4 lbs
2 .1
1 .04
9 x 48 in
2 .1
2 .1
, Operating Temperature: 35 - 100° F or 1.7 – 38° C
2
OMNI FILTER
293 Wright Street
Delavan, WI 53115
PH: (800) 937-6664
OM40K
10 .7
15 .0
18,143 @ 4.12
41,386 @ 20.0
4,396/lb Salt @ 4.1 lbs
2 .7
1 .25
10 x 44 in
2 .7
2 .7
Tested and
Certified by the
WQA against NSF/
ANSI Standard
44 for softener
performance &
372 for "lead free"
compliance.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Om40k

Table des Matières