Performance Data Sheet - Omnifilter OM26K Manuel

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PERFORMANCE DATA SHEET

Model
Rated Service Flow (gpm)
Pressure Drop at Rated
Service Flow Rate (psid)
Rated Capacity
(grains @ lb of salt)
Rated Efficiency
(grains/lb Salt @ lb of salt)
Maximum Flow Rate During
Regeneration (gpm)
Indion 225 NaF
Ion Exchange Resin (cu ft)
Tank size
Backwash - GPM
Rapid Rinse/purge - GPM
Operating Pressure:20 -125 psi or 1.4 – 8.8 kg/Centimeter2, Operating Temperature: 35 - 100° F or 1.7 – 38° C
Acceptable Salt Type: Sodium Chloride – Pellet salt
All Systems above tested at 35psi +/- 5 psi, pH of 7.5 +/- 0.5,
Capacity Testing Flow Rate = 50% of the rated service flow rate for the various size systems.
These water softener systems have been tested by WQA and conform to NSF/ANSI 44 for specific
performance claims as verified and substantiated by test data. The rated salt efficiencies above were also
determined in accordance with NSF/ANSI 44 and are only valid at the salt dosage referenced above. An
efficiency rated water softener is a demand initiated regeneration (DIR) softener which also complies with
specific performance specifications intended to minimize the amount of regenerant brine and water used
in its operation. Efficiency rated water softeners shall have a rated salt efficiency of not less that 3350
grains of total hardness exchanged per pound of salt (based on NaCl equivalency) (477 grams of total
hardness exchanged per kilogram of salt), and shall not deliver more salt than its listed rating. The rated
efficiency of the water softener, the salt dosage at that efficiency, the capacity at that salt dosage and
that of the efficiency is only valid at the stated salt dosage. Efficiency is measured by a laboratory test
described in NSF/ANSI 44. The test represents the maximum possible efficiency the system can achieve.
Operational efficiency is the actual efficiency achieved after the system has been installed. It is typically
less than the efficiency due to individual application factors including water hardness, water usage, and
other contaminants that reduce the water softener's capacity . These systems are not intended to be used
for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before
or after the system. Refer to the system Installation and Service Manuals for set-up and programming
instructions.Contact your local OMNI FILTER dealer for parts and service. See your owners manual for
warranty information .
Important Notice: For conditions of use, health claims certified by the California Department of Public
Health and replacement parts, see product data sheet
Iowa Requirement:
Seller: ________________________________________________ Date: _________________________
Buyer: ________________________________________________ Date: _________________________
7/29/10
OM26K
8 .0
12 .0
11,513 @ 2.6
26,089 @ 12.6
4,426 lbs salt @ 2.6 lbs
1 .7
0 .81
8" x 44"
1 .7
1 .7
OMNI FILTER
293 Wright Street
Delavan, WI 53115
PH: (800) 937-6664
Tested and Certified
by the WQA against
NSF/ANSI Standard 44
& ORD 0902 for "lead
free" compliance.
OM26K SE10 • 19