5.
Take out the orifice support, and then use a 6 mm socket
and wrench or 6 mm nut driver to remove the LP orifice at
the end of the supply pipe. Replace with Natural gas
orifice.
A.
B.
IMPORTANT: Check that the orifice is properly installed
inside of the supply pipe.
6.
Reinstall the spider guard, access cover, and wind baffle.
7.
Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
A.
Gas supply line
Shutoff valve "open" position
B.
C.
To grill
8.
Test all connections by brushing on an approved
noncorrosive leakdetection solution. Bubbles will show a
leak. Correct any leak found.
The igniter battery is not factory installed. A "AA" size
9.
alkaline battery is located in the accessory box on the grill
grate. Install battery at this time following the instructions
in "Replacing the Igniter Battery" section.
10. Go to "Check and Adjust the Burners" section.
Record Conversion
The LP appliance nameplate is located inside the grill cabinet
on the left-hand side. Once converted, place the NG appliance
nameplate as close as possible to the current LP appliance
nameplate without covering it.
In the last page of the Use and Care Guide, write "Converted to
Natural Gas". Also record the conversion date and the
technician/company that performed the conversion.
A
B
Orifice Support
Orifice
16