Troubleshooting
The failures and solutions stated in this section can be performed easily by yourselves and always consult to an
Authorized Uğur Service if these suggestions do NOTE solve your problem.
CAUTION!
• Intervention to any failure that may occur in your product must be carried out by Authorized Uğur
Service.
• Any intervention that may be done by you may harm you, your employee or customer, invalidate the
product guarantee and cause material damage (fire etc..).
• In case of any failure, consult to Uğur Customer Care or Authorized Uğur Service. (see Page 20)
Troubleshooting
Cooler is NOTE working. (No sound
or only fan sound comes from the
product.)
Device internal temperature is high.
Device internal temperature is very
low.
High degree of sweating on the
glass and inside the device.
Bad smell coming from the bottom
part of the cooler.
Setting the digital thermostat values other than the factory settings are completely under the
user's responsibility. Our company shall NOTE be held responsible for the material and moral
losses that may arise in connection thereto.
Possible Solution
It may be due to the thermostat
NOTE plugged in. The fuse may be
blown or broken down.
Condenser lamella may be ob-
structed or get dirty.
External ambient temperature is
very high or wrong thermostat
setting.
Very close to the back wall, ventila-
tion shutters are obstructed or it's
front is prevented.
It may have been expose to exces-
sive external wind.
Condenser lamellas are very dirty.
Wrong internal thermostat setting.
Water discharge hole may be
obstructed when sweating is seen
inside the cabin.
In glass sweating on the other hand,
current external ambient humidity
is over 65%.
Lower water discharge tray is dirty.
55
Result.
It will run again when reached to
the suitable temperature.
Insert the plug properly.
Consult to an Authorized Uğur Ser-
vice or a competent electrician.
Clean the condenser lamellas.
Move the cooler to a place where
the external temperature is lower.
Adjust to the stated gap.
Clean in front of the ventilation
shutters.
Prevent the wind.
Clean the condenser lamellas.
Re-set the thermostat.
Clean water discharge hole. With re-
gards to the high humidity, you can
move your cooler to an environment
with less humidity.
Clean the water discharge tray.