Do Not Operate in Freezing Outdoor Conditions
This cool-only air conditioner was not designed for
freezing outdoor conditions . It must not be used in
freezing outdoor conditions .
Remote Control
To ensure proper operation, aim the remote
n
control at the signal receiver on the air
conditioner .
Make sure nothing is between the air conditioner
n
and the remote control that could block the
signal .
Cool Mode
Use the Cool mode at Low, Med, High or Auto Fan
Speed for cooling . Use the Temperature Increase ▲
/ Decrease ▼ pads to set the desired temperature
between 64°F and 86°F in 1°F increments .
An electronic thermostat is used to maintain the room
temperature . The compressor will cycle on
and off to keep the room at the set level of comfort .
Set the thermostat at a lower number and the indoor
air will become cooler . Set the thermostat at a higher
number and the indoor air will become warmer .
NOTE: If the air conditioner is off and is then turned on
while set to a Cool setting or if turned from a fan
setting to a Cool setting, it may take approximately
3 minutes for the compressor to start and cooling to
begin.
Energy Saver Mode
This mode optimizes the cooling power of your air
conditioner, thereby saving you energy . Once the
set point temperature has been reached, the fan
will cycle off to save energy . The fan will cycle back
on periodically to insure all cooling capacity in the
system is used . This mode is the default mode for the
unit . Each time the unit is powered off, it will restart
in Energy Saver mode ON . This includes Delay timer
mode . The first time the unit is turned on, the settings
will be 70° and Low fan . You can adjust the fan
speed and temperature to your personal comfort .
Fan Only Mode
Use the Fan Only Mode at Low, Med or High fan
speed to provide air circulation and filtering without
cooling . Since fan-only settings do not provide
cooling, a Set temperature cannot be entered . The
room temperature will appear in the display .
Auto Fan Speed
Set to Auto fan speed for the fan speed to
automatically set to the speed needed to provide
optimum comfort settings with the set temperature .
If the room needs more cooling, the fan speed
Power Outage Recovery Feature
In the case of a power outage or interruption, the
unit will automatically restart in the settings last
used after the power is restored . If the Delay 1–24hr
The remote control signal has a range of
n
up to 20 feet .
Make sure batteries are fresh and installed
n
correctly as indicated on the remote control .
Remote contains a magnet allowing it to attach
n
to metal surfaces .
Cooling Descriptions
For Normal Cooling—Select the Cool mode and
High or Med fan with a middle set temperature .
For Maximum Cooling—Select the Cool mode
and High fan with a lower set temperature .
For Quieter and Nighttime Cooling—Select the
Cool mode and Low fan with a middle set
temperature .
Energy Saver ON—Helps minimize electricity use .
It is normal for the fan to cycle off and then back
on in this mode . This on/off cycle can repeat
multiple times . Because the fan will cycle off, you
may notice a variation in room temperature and
humidity .
Energy Saver OFF—When this mode is not engaged,
the fan will run continuously, and in Cool mode the
compressor will cycle on and off to maintain room
temperature .
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
will automatically increase . If the room needs less
cooling, the fan speed will automatically decrease .
NOTE: Auto Fan Speed cannot be used when in the
Fan Only Mode.
feature was set, it will resume countdown . You may
need to set a new time if desired .