INSTALL THE ENERGIZER

1. Connect Battery
One 12 volt ba ery or two 9 volt ba eries*.
Connec ng a 12V ba ery
Red
ALWAYS leave ba ery (ba eries) disconnected during storage.
2. Earth System
Earthing the energizer is the key
to a successful Power Fence. We
recommend using a galvanised earth
stake, driven 1m (3 ) into the ground.
3. Connect to earth & fence
1.
Connect the earth stake to the
green energizer terminal using
the green leadset provided.
The wire must be fi rmly
clamped to the earth stake.
2.
Connect the fence line to the
red energizer terminal using
the red leadset provided. The
wire must be fi rmly clamped
to the fence wire.
8
Gallagher 3E1922 Ba ery Powered Energizer User Manual
Black
Ba ery
Connec ng a 9V ba ery
B100 only
Red (+)
Black (-)
*Always use two 9V ba eries
Minimum 1m
Red
Green
Ba eries

Publicité