AEG HKB64450NB Notice D'utilisation page 10

Masquer les pouces Voir aussi pour HKB64450NB:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10
www.aeg.com
the ground connection agrees with the
standards and regulations.
• Do not let the power cable to heat up
to a temperature higher than 90° C.
If the pilot lights turn on after
connecting the hob to the
mains, turn on and off the
control knob and wait until
the residual heat indicator
goes out.
3.6 Connection cable
To replace the connection cable use only
the special cable or its equivalent. The
cable type is: H03V2V2-F T90.
Make sure that the cable section is
applicable to the voltage and the working
temperature. The yellow / green earth
wire must be approximately 2 cm longer
than the brown (or black) phase wire.
1. Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol
, or coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the
letter 'N' or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the
letter 'L'. It must always be connected
to the network phase.
L
N
3.7 Assembly
1.
2.
3.
min.
100 mm
min.
55 mm
30 mm
+
2
480 mm
0
4.
min.
650 mm
2
+
560 mm
0