To prevent high concentrations of oxygen:
1.
Keep the equipment in a well-ventilated area.
2.
Do not carry equipment under a coat or any form of clothing.
3.
Turn off oxygen supply by turning the rotary selector to the OFF position when not in use.
waRNING
To reduce the risk of injury:
1.
Keep all units away from children. Do not allow unauthorized or untrained individuals to operate the equipment. Never tamper with or try to repair the equipment yourself. If you have any
questions or suspect your equipment is not operating properly, contact your oxygen provider.
2.
Do not immerse in liquids or subject device to harsh conditions.
3.
Do not use with other equipment (i.e. humidifier, nebulizer, mask, etc.) when in PulseDose delivery mode.
4.
Do not use in temperatures greater than 104°F (40°C) or below 14°F (-10°C).
5.
Equipment not suitable for use in the presence of a flammable anesthetic mixture with air or with oxygen or nitrous oxide.

Physician's Notes

1.
Use only continuous flow iFill oxygen cylinders (535-CF series) with patients who breathe below 6 Breaths Per Minute (BPM) or above 40 BPM.
2.
Use only continuous flow iFill oxygen cylinders (535-CF series) with patients who consistently fail to trigger equipment (i.e. mouth breathing with closed soft palates).
3.
Verify patient is getting adequate Pa02 or Sa02 levels in PulseDose delivery.
4.
Use only standard nasal cannula with PulseDose delivery. Do not use pediatric (low-flow) nasal cannula or mask with PulseDose delivery.
5.
A mask or any nasal cannula can be used with continuous flow delivery.
6.
The PD1000A series electronic conserving device contains an internally controlled preset 2 LPM continuous flow backup. The service manual describes how to change the cannula fitting to
obtain a 3, 4, 5 or 6 LPM continuous flow backup.

INTRODUCTION

Indications For Use (PD1000a Series)
The DeVilbiss iFill Oxygen Cylinders w/integrated PD1000A are intended as a delivery device for 93%
allows patients to ambulate longer than they would with a continuous flow regulator on the same cylinder.

How Conserving Devices work

Conserving devices extend the use time from a supply of oxygen, thereby offering increased mobility with improved comfort and efficiency. This is accomplished by delivering oxygen only during
inhalation – using a short "pulse" or several "pulses" of oxygen -- as opposed to continuous flow systems which deliver oxygen throughout the entire breathing cycle; this conservation can result in
your oxygen system lasting two to four times longer.
Because oxygen is released only during inhalation, the constant flow of oxygen into the nostrils is eliminated, resulting in a more comfortable treatment for many users. The pulse(s) are almost
undetectable, and the humidity in the room air helps maintain a normal level of moisture in the nasal cavity. This greatly reduces the discomfort of dehydration associated with a continuous flow
oxygen system.

USE TIMES

Because PulseDose responds to each individual's breathing patterns, the use time will vary for each individual depending on the prescription rate and the breath rate. The following chart shows the
theoretical ambulatory ranges based on a 3 to 1 conserving ratio.
NOTE
–All ambulatory ranges are calculated assuming a breath rate of 20 breaths per minute in PulseDose (PD) mode.
Delivered Volume cc's:
16.5
Flow Rate
iFill M4 Cylinder
113 Gaseous Liters
iFill M6 Cylinder
164 Gaseous Liters
iFill ML6 Cylinder
170 Gaseous Liters
iFill C Cylinder
240 Gaseous Liters
12.1
iFill D Cylinder
415 Gaseous Liters
21.0
11.4
iFill E Cylinder
682 Gaseous Liters
34.4
CF=Continuous Flow
PD=3 to 1 Conserving Device
Specifications subject to change without notice. This chart is intended to be used only as a guide.
Cylinders vary in gaseous liter capacity by manufacturer which may result in varying use times.
A-535-CYL
Use Times Shown In Hours
24.75
33
1
1.5
2
1.9
1.3
.9
5.7
3.8
2.9
2.7
1.8
1.4
8.3
5.5
4.1
2.8
1.9
1.4
8.6
5.7
4.3
4.0
2.7
2.0
8.1
6.1
6.9
4.6
3.5
14.0
10.5
7.6
5.7
23.0
17.2
±
3% oxygen from high-pressure oxygen cylinders. This is an ambulatory device, which
41.25
49.5
66
2.5
3
4
.7
.6
.5
2.3
1.9
1.4
1.1
.9
.7
3.3
2.8
2.1
1.1
.9
.7
3.4
2.9
2.1
1.6
1.3
1.0
4.9
4.0
3.0
2.8
2.3
1.7
8.4
7.0
5.2
4.6
3.8
2.8
13.8
11.5
8.6
82.5
99
5
6
MODE
.4
.3
CF
1.1
.9
PD
.6
.4
CF
1.7
1.4
PD
.6
.5
CF
1.7
1.4
PD
.8
.7
CF
2.4
2.0
PD
1.4
1.2
CF
4.2
3.5
PD
2.3
1.9
CF
6.9
5.8
PD
EN - 3