The pump output pressure is set at the factory. There is no need to alter the output pressure adjustment valve unless
the pump includes a specific adjuster. Altering the output pressure may damage the machine and void the product
warranty.
SEALED
The pumps are manufactured in a way that requires no maintenance. The pumps are oil-filled during production and
do not require breather caps, oil changes or have an oil sight glass or oil filler. Pump appearance and features are:
1.
Pump Inlet
2.
Pump Outlet
3.
Detergent Port
4.
Pressure Release Valve
5.
Output Pressure Adjustment Valve
HOSES AND FITTINGS
The machine comes with necessary hoses and fittings.
TURBO-HEAD ASSEMBLY
If the "turbo head" and turbo-head is not assembled, 1) wrap the threaded part of the turbo-head adaptor fitting
with plumbers Teflon tape (not supplied), then 2) screw the adaptor into the turbo-head, then 3) use an Allen key
through the adaptor to tighten it firmly to the turbo-head.
"QUICK-CONNECT" TYPE CONNECTORS
1.
Ensure the connectors are clean.
2.
Pull back on the knurled ring until the ball bearings are visible and hold it in this position, then insert the male
connector into the female. When the parts are fully connected, release the knurled ring.