Télécharger Imprimer la page

BFT SHYRA AC SL Instructions D'installation page 21

Masquer les pouces Voir aussi pour SHYRA AC SL:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
1) GENERAL INFORMATION
The SHYRA AC SL / SHYRA AC BA control panel comes with standard factory
settings.
Any change must be set by means of the TRIMMER and DIP SWITCH settings.
Its main features are:
- Control of 1 single-phase motor
- Separate inputs for safety devices
- Built-in radio receiver rolling code with transmitter cloning.
The board has a terminal strip of the removable kind to make maintenance or re-
placement easier. It comes with a series of prewired jumpers to make the installer's
job on site easier. The jumpers concern terminals: 70-71, 70-72, 70-74. If the
above-mentioned terminals are being used, remove the relevant jumpers.
TESTING
The SHYRA AC SL / SHYRA AC BA panel controls (checks) the start relays and
safety devices (photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
2) TECHNICAL SPECIFICATIONS
Power supply
Panel dimensions
Low voltage/mains insulation
Operating temperature range
Dielectric rigidity
Accessories power supply
AUX 0 - Flashing
Contact powered
Fuses
Built-in Rolling-Code
radio-receiver
Setting of parameters and logics TRIMMER + DIP SWITCH
N° of combinations
Max. n° of remotes that can be
memorized
Pedestrian work time
Maximum power
Maximum work time
Usable transmitter versions:
All ROLLING CODE transmitters compatible with
3) TUBE ARRANGEMENT Fig. A
Install the electrical system referring to the standards in force for electrical systems
CEI 64-8, IEC 364, harmonization document HD 384 and other national standards.
4) TERMINAL BOARD WIRING Fig. C
For the electric diagram and the cross section of the cables refer to the
manual of the actuator.
Once suitable electric cables have been run through the raceways and the auto-
mated device's various components have been fastened at the predetermined
points, the next step is to connect them as directed and illustrated in the diagrams
contained in the relevant instruction manuals. Connect the live, neutral and earth
wire (compulsory).
WARNINGS - When performing wiring and installation, refer to the standards
in force and, whatever the case, apply good practice principles. Wires carrying
different voltages must be kept physically separate from each other, or they must
be suitably insulated with at least 1mm of additional insulation.
Wires must be secured with additional fastening near the terminals, using devi-
ces such as cable clamps. All connecting cables must be kept far enough away
from dissipaters.
WARNING! For connection to the mains power supply, use a multicore cable
with a cross-sectional area of at least 3x1.5mm
the regulations in force.
To connect the motors, use a cable with a cross-sectional area of at least
1.5mm
of the kind provided for by the regulations in force.
2
The cable must be type H05RN-F at least.
5) SAFETY DEVICES
Note: only use receiving safety devices with free changeover contact.
5.1) TESTED DEVICES Fig.G
5.2) CONNECTION OF 1 PAIR OF NON-TESTED PHOTOCELLS FIG. B
WARNING!
The values of the impact force according to EN 12453 are only observed with
the use of safety edges (active) connected to the board.
6) MEMORIZING TRANSMITTERS FIG. D
RADIO
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the first transmitter assigns the RECEIVER'S
INSTALLATION MANUAL
120V 60Hz (SHYRA AC SL / SHYRA AC BA 120V)
220-230V 50/60 Hz (SHYRA AC SL / SHYRA
AC BA 230V)
Fig. F
> 2MOhm 500V
-20 / +55°C
mains/LV 3750V~ for 1 minute
4V~ (demand max. 0,2A)
120V~ 40W max ( SHYRA AC SL / SHYRA AC
BA 120V )
230V~ 40W max ( SHYRA AC SL / SHYRA AC
BA 230V )
Fig. C
frequency 433.92MHz
4 billion
63
8 s.
500W
120s - SHYRA AC SL
10s - SHYRA AC BA
.
of the kind provided for by
2
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced features:
Cloning of master transmitter (rolling code or fixed code).
Cloning to replace transmitters already entered in receiver.
Transmitter database management.
Receiver community management.
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
7) REVERSING THE OPENING DIRECTION (Fig.E)
8) ADJUSTMENT PROCEDURE
- Before turning the unit on, check electrical connections.
- Set the following parameters:
Automatic Closing Time,
Work Time (for SHYRA AC SL only).
- Set the logics.
WARNING! Incorrect settings can result in damage to property and injury
to people and animals.
WARNING: Check that the force of impact measured at the points pro-
vided for by standard EN 12445 is lower than the value laid down by
standard EN 12453.
KEYS
KEYS
Description
Add Start Key
S1
associates the desired key with the Start command.
Add Pedestrian Key (SHYRA AC SL)
associates the desired key with the pedestrian command.
S2
Add Open key (SHYRA AC BA)
associates the desired key with the open command.
S2
Confirms the changes made to parameter settings and operating
>5s
Erase List
S1+S2
WARNING! Erases all memorized transmitters from the
>10s
receiver's memory.
LED INDICATORS:
POWER
Steadily lit: - Mains power on - Board powered - Fuses intact
START
Lit: START input activated
OPEN
Lit: OPEN pedestrian input activated
STOP
Unlit: STOP input activated
PHOT
Unlit: PHOT photocell input activated
FAULT 1 PHOT input safety device test input diagnostics
BAR
Unlit: BAR safety edge input activated
FAULT 2 BAR input safety device test input diagnostics
Unlit: leaf fully closed
SWC
Lit: motor limit switch is disengaged
Flashing: end of the work time while closing
Unlit: leaf fully open
SWO
Lit: motor limit switch is disengaged
Flashing: end of the work time while opening
Unlit: no error
ERR
LIT: see error diagnostics table
Unlit: remote programming not active
Radio LED only flashing: Remote programming active, waiting for
hidden key.
RADIO
(GREEN)
Flashing in sync with Set LED: Transmitter deletion in progress
Lit: remote programming active, waiting for desired key.
Lit 1s: Radio receiver channel activated
Lit: see error diagnostics table
SET
Flashing in sync with Radio LED: Transmitter deletion in progress
21
SHYRA -

Publicité

loading

Ce manuel est également adapté pour:

Shyra ac sl 120Shyra ac baShyra ac ba 120