GENERAL
Carefully read the following important information regarding
installation safety and maintenance. Keep this information
booklet accessible for further consultations.
The appliance has been designed for use in the filtering ver-
sion (air circulation on the inside – Fig.1A).
SAFETY PRECAUTION
1. Take care when the cooker hood is operating simultane-
ously with an open fireplace or burner that depend on the air
in the environment and are supplied by other than electrical
energy, as the cooker hood removes the air from the environ-
ment which a burner or fireplace need for combustion. The
negative pressure in the environment must not exceed 4Pa
(4x10-5 bar). Provide adequate ventilation in the environment
for a safe operation of the cooker hood.
Follow the local laws applicable for external air evacuation.
Before connecting the model to the electricity network:
- Control the data plate (positioned inside the appliance)
to ascertain that the voltage and power correspond to the
network and the socket is suitable. If in doubt ask a qualified
electrician.
- If the power supply cable is damaged, it must be replaced
with another cable or a special assembly, which may be
obtained direct from the manufacturer or from the Technical
Assistance Centre.
- This device must be connected to the supply network
through either a plug fused 3A or hardwired to a 2 fase spur
protected by 3A fuse.
2. Warning !
In certain circumstances electrical appliances may be a
danger hazard.
A) Do not check the status of the filters while the cooker
hood is operating
B) Do not touch bulbs or adjacent areas, during or straight
after prolonged use of the lighting installation.
C) Flambè cooking is prohibited underneath the cooker
hood
D) Avoid free flame, as it is damaging for the filters and
a fire hazard
E) Constantly check food frying to avoid that the
overheated oil may become a fire hazard
F) Disconnec t the elec trical plug prior to any
maintenance.
G) This appliance is not intended for use by young children
or infirm persons without supervision
H) Young children should be supervised to ensure they do
not play with the appliance
I) There shall be adequate ventilation of the room when
the rangehood is used at the same time as appliances
burning gas or other fuels
L) There is a risk of fire if cleaning is not carried out in
accordance with the instructions
This appliance conforms to the European Directive EC/2002/96,
Waste Electrical and Electronic Equipment (WEEE). By making
sure that this appliance is disposed of in a suitable manner,
the user is helping to prevent potential damage to the
environment or to public health.
ENGLISH
The
symbol on the product or on the accompanying
paperwork indicates that the appliance should not be treated
as domestic waste, but should be delivered to a suitable
electric and electronic appliance recycling collection point.
Follow local guidelines when disposing of waste. For more
information on the treatment, re-use and recycling of this
product, please contact your local authority, domestic waste
collection service or the shop where the appliance was
purchased.
INSTALLATION INSTRUCTIONS
Assembly and electrical connections must be carried out
by specialised personnel.
• Electric Connection
Note: Verify the data label placed inside the appliance:
- If the symbol
the instructions concerning insulation class I.
Insulation class I
Warning:
This is a class I, appliance and must therefore be connected
to an effiecient earthing system.
The appliance must be connected to the electricity supply
as follows:
BROWN = L live wire
BLUE = N neutral
YELLOW / GREEN =
The neutral wire must be connected to the terminal with the N
symbol while the YELLOW / GREEN, wire must be connected
to the terminal by the earth symbol
Warning:
When connecting the appliance to the electricity supply, make
sure that the mains socket has an earth connection.
After fitting the ducted cooker hood, make sure that the
electrical plug is in a position where it can be accessed
easily.
If the appliance is connected directly to the electricity supply,
an omnipolar switch with a minimum contact opening of
3 mm must be placed in between the two; its size must
be suitable for the load required and it must comply with
current legislation.
• If the hob is electric, gas, or induction, the minimum distance
between the same and the lower part of the hood must be
at least 65 cm.
If a connection tube composed of two parts is used, the upper
part must be placed outside the lower part.
Do not connect the cooker hood exhaust to the same conduc-
tor used to circulate hot air or for evacuating fumes from other
appliances generated by other than an electrical source.
Attention! This product is only supplied in the FILTERING
version.
• Hood installation
- Position the drill hole template on the ceiling making sure
that the arrow is positioned on the same side of the appli-
- 21 -