_900_serie.book Seite 39 Mittwoch, 22. März 2006 4:28 16
IU0U automatic charger
Note
Only use cables with the prescribed wire-cross sections for the
connection of the IU0U automatic charger to the battery:
Article No.
945-012TB 945-012TC
925-024TB 925-024TC
925-012TB 915-024TB
925-012TC, 915-024TC
915-012TB
915-012TA, 908-024TA
➤ Lay the cables from the batteries to the IU0U automatic charger.
➤ Crimp the cable ends with the multicore cable ends.
Note
Use for the connection of starter batteries to the unit variants 925-
012TC, 915-025TC and 915-012TB the specially intended
terminal (see figure 11, page 7). Provide the cable with a fork
connection for an optimum connection with the terminal (see
figure 12, page 7).
Note
The negative pole of the battery is earth-connected in the
connected status.
Attention
Ensure correct polarity. The internal flat-pin terminal triggers with
the wrong polarity of battery and battery charger. The repair must
only be carried out by skilled personnel familiar with the dangers
involved and aware of the relevant regulations.
➤ Connect the "-" (minus) battery pole with a connecting cable with the "-
" (minus) terminal at the IU0U automatic charger (see figure 10, page 7).
➤ Connect the "+" (plus) battery pole with the connecting cable with the
"+" (plus) terminal at the IU0U automatic charger (see figure 10, page 7).
Supply battery
2
2
25 mm
- 30 mm
2
2
25 mm
- 30 mm
2
2
6 mm
-10 mm
2
2
6 mm
-10 mm
Installation
Starter battery
Function is not available
2
2
1 mm
-2.5 mm
2
2
1 mm
-2.5 mm
Function is not available