Waeco PerfectCharge IU1512 Notice D'emploi page 37

Chargeur automatique de batteries iu0u
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 50
_900_serie.book Seite 37 Mittwoch, 22. März 2006 4:28 16
IU0U automatic charger
Note
If you do not have sufficient technical knowledge in respect of the
installation and connection of electrical components in the
vehicles, let the IU0U automatic charger be installed by a
specialist.
Please note the following when installing the unit:
Select a well ventilated location which is protected against humidity.
The installation surface must be level and of sufficient strength.
Make sure that no ventilation surfaces on the unit are covered when
installing.
For further safety notes when installing the unit see Chapter „Safety when
handling electrical wires" on page 30.
5.1
Settings on the unit
Charging voltage and time limitation
The required charging voltage and the period for the main charging phase
(U0 phase, see also Chapter „Charging characteristic" on page 42) are
selected via a switch field on the unit (see figure 13, page 7):
Note
Ask your battery dealer for the charging voltage and the required
timer setting for your batteries.
Caution!
Make sure that the unit is never operated when the switches 1 and
2 or 3 and 4 are at the same time in position "ON". Only the switch
positions as described in the following tables ensure correct
functioning of the IU0U automatic charger.
Settings for the charging voltage for 945-012TB, 945-012TC, 925-012TB,
925-012TC, 915-012TB and 915-012TA:
Charging
voltage
13,8 V
14,4 V
14,8 V
Switch 1
Switch 2
OFF
OFF
ON
OFF
OFF
ON
Installation
Application range
Old starter batteries,
mains charger operation
Wet and gel batteries
Fleece batteries
37

Publicité

Table des Matières
loading