_900_serie.book Seite 33 Mittwoch, 22. März 2006 4:28 16
IU0U automatic charger
The unit is equipped with a wrong polarity protection. A fuse protects against
damage of the unit in the case of wrong polarity. Regarding type and valency
of the fuse in your unit see Chapter „Technical data" on page 47.
Attention
The replace of the unit fuse must only be carried out by a qualified
specialist who is familiar with the dangers involved and aware of
the relevant regulations.
Note
A temperature sensor (accessory) which is connected at the
battery being charged protects the battery against damage in the
case of high or low outside temperature by adapting the charging
voltage of the temperature to the battery (see Chapter „Charging
characteristic" on page 42).
A control lamp on the unit or three control lamps on the remote control enable
a constant monitoring of the IU0U automatic charger (see Chapter
„Functional check" on page 44).
4.2
Specifications of the unit variants
The IU0U automatic charger of the series 900 of WAECO are delivered in
different unit variants.
Your IU0U automatic charger can charge batteries up to a determined
battery capacity (see Chapter „Technical data" on page 47).
Regarding the identification of the specification of your unit, compare the item
number on the type plate with the data in the following tables.
Your IU0U automatic charger has following switches, displays and
connections (see figure 1-9, page 3-6):
Note
The diagrams outline how the battery is connected to the charger.
With a 24 V charger the battery diagram refers to two 12 V batte-
ries connected in series.