TO REPLACE THE STYLUS
• Put the rest clip on the pick-up arm.
• Remove Headshell (5) from the tonearm.
• Remove the protective cap from the stylus.
• Pull the stylus to the lower front and remove it.
• Put in the new stylus following the reverse procedure.
• Replace the protective cap on the stylus.
TO REMOVE THE CARTRIDGE
• Put the rest clip on the pick-up arm.
• Remove headshell (5) from the tonearm.
• Remove the stylus to prevent damage.
• Remove the two cartridge fixing screws.
• Disconnect the four link wires at the back of the cartridge.
TO INSTALL NEW CARTRIDGE
• Connect the four link wires.
• Take care of the receptacle's colors.
• Install the cartridge in the head shell.
• Install the two cartridge fixing screws.
• Re-install the stylus.
• Replace the protective cap on the stylus.