INSTALLATION
Follow the mounting drawings on page 2.
1.
Do NOT remove the hood from the packaging. The hood will be mounted while still in the box. When the hood
has been fully mounted at the optimum height, the box can be removed from the hood. Turn the box so the text
"FRONT" is in the correct position. "FRONT" must be facing the side where the person cooking will be able to see
the display on the hood.
2. Attaching the mounting plates:
- Take the drilling jig from this mounting instruction (see the centre page of this booklet).
- Cut the drilling jib in half as indicated.
- Mark the central line of the drilling jigs. Make sure that the hood is mounted in the centre over the cooking plate.
- The distance between the centres of both mounting plates is 840 mm (or 420 mm measured from the central line).
- Mark the 4 drilling holes on each mounting plate.
In view of the substantial own weight of the hood, the ceiling must have sufficient load bearing capacity.
Bear in mind that the electrical connection must be placed behind the right-hand mounting plate.
3.
Attach each of the mounting plates with four screws (906.192) unto the ceiling. Here pay attention to the position of the
electrical
connection.
4.
- Lift up the packaging including the hood with at least 2 persons. Make sure that the connecting cable is on the right-
hand side.
- Position the packaging/hood at a certain height, making sure that the mounting cables can easily be placed into the
mounting plates.
- Take the ends of the four mounting cables and insert them into the holes of the mounting plates and pull them through
the slot downwards, as shown in the figure.
The height adjustment will be dealt with later (illustration 6)
5. Electrical connection:
Slide the closing plate over the mounting cables until it almost touches the mounting plate. Connect the power supply
cable to the connector. Replacement of the connection cable is to be done by a qualified installer. The amperage and the
energy consumption have been indicated on the specification label attached to the inside of the hood.
6.
Slide both closing plates over the cables until they touch the mounting plates. Attach each closing plate with two
screws (906.145) into the mounting plate.
7. Adjust the height:
The height of the hood with respect to the ceiling can be between 250 and 1500 mm. The recommended mounting height
for an electrical or ceramic cooking plate is min. 600 mm and max. 850 mm. The mounting height for a gas or induction
cooking plate is min. 650 mm and max. 850 mm.
The cable clamps are found at the place where the cable enters the hood. The cable can be extended by pressing this
cable clamp. The cable will be locked as soon as the cable clamp is no longer pressed. The cable can still be slid in at this
moment. The visible length of the power supply cable can be adjusted by sliding it into the hood.
ATTENTION:
• While adjusting the cables, support the hood in order to prevent it from falling.
• Do not exceed the maximum height to the ceiling (1500 mm).
Carefully remove the hood from the packaging.
Optionally, an accessory with four longer cables of 3,5 metres can be ordered (item number 7550100).
EN 11