4 Appendix

4.1 Specifications/Technische Daten

NETWORK AND GENERAL FEATURES
Remote Control and Software
Maximum Configuration
Supervised Amplifier Parameters Operation mode, temperature, output volta-
Network Supervision
Audio Monitoring
AUDIO SPECIFICATIONS
Analog Audio Input
Input Level (nominal)
Input Level (max. before clip)
A/D Conversion
Digital Audio Input
Input Sample Rates
Audio Output
Output Level (nominal)
Output Level (max. before clip) +21 dBu / 8.7 V
D/A Conversion
Monitor Outputs
68
RCM-26 Remote Control Module
IRIS-Net™, Multiple PCs possible, MS Win-
dows 98, 2000, XP
250 Amplifiers in total, 100 Amplifiers per
CAN bus, 1000 meter cable run
ge and current, impedance of connected
speakers, protection mode status, mains
voltage and current, power consumption, pi-
lot tone detection
CAN bus failures, defective or missing am-
plifiers, bandwidth, failure protocol and mes-
saging
All input and output signals
2 audio inputs on internal slot connector,
pre-/post fader selectable
+6 dBu / 1.55 V
+21 dBu / 8.7 V
24 Bit linear, Sigma-Delta, 128 times over-
sampling
AES3 (AES/EBU) format, XLR In/Thru con-
nectors
32 kHz...192 kHz, internal Sample-Rate-
Converter
2 audio outputs on internal slot connector
+6 dBu / 1.55 V
24 Bit, Sigma-Delta, 128 times over-sam-
pling
2 x RJ-45 (REMOTE), electronically sym-
metric (Pins 7/8)