top in order to better channel the fumes outside.
Avoid using angled pipes, make sure that the pipes are at least of the minimum length.
Comply with the current regulations on air discharge into the atmosphere.
If a boiler, stove, fireplace, etc. that uses gas or other fuels is being used at the same time,
make sure the room where the fumes are extracted is well ventilated, in compliance with the
current regulations.
Mounting instruction: see section "O" of the booklet.
D
ELECTRICAL CONNECTIONS
(Section reserved for qualified installers)
WARNING!
Before doing any work inside the range hood, disconnect the appliance from the mains
power supply. Check that the wires inside the range hood are not disconnected or cut; if
this is the case, contact your nearest service centre. The electrical connections must be
performed by qualified personnel.
The connections must be performed in compliance with the legal standards in force. Check
that the relief valve and the electrical system are able to support the load of the appliance (see
the technical specifications in point B).
Some types of appliance are supplied with a cable without plug; in this case, "standardised"
plugs must be used, keeping in mind that:
- the yellow-green wire must be used for the earth,
- the blue/white wire must be used for the neutral,
- the brown/black wire must be used for the phase; the cable must not come into contact with
hot parts (over 70° C).
- fit a plug that is suitable for the load to the power cable, and connect it to a suitable power
outlet.
For appliances that come supplied with cable and plug please ensure they are plugged into a
circuit suitable for this appliance.
Please refer to a qualifed person. (See technical specifications in point B).
The manufacturer declines all liability if the safety standards are not observed.
E
RANGE HOOD WITH OUTSIDE DISCHARGE
In this version, the fumes and steam from the kitchen are conveyed outside through an exhaust
duct. The exhaust conveyor that protrudes from the upper part of the range hood must be con-
nected to a duct that carries the fumes and steam outside. In this version, the charcoal filters,
if fitted, should be removed; to do this, see the instructions in point F. There must be adequate
ventilation of the room when the range hood is used at the same time as appliances burning
gas or other fuels, according to the standard.
Deviation for Germany:
When the range hood and appliances supplied with energy other than electricity are simulta-
neously in operation, the negative pressure in the room must not exceed 4 Pa (4x10 E-5 bar).
F
RECIRCULATING RANGE HOOD
In this version, the air passes through charcoal filters for purification, and is then recirculated
back into the kitchen.
Check that the charcoal filters are fitted to the motor, and if not, install them as described in
the instructions in point H.
If the hood is of filtering type, remove the non-return valve fitted at the motor's outlet.
14
(exhaust)
(with filter)