Télécharger Imprimer la page

Before You Start / On-Off Switch And Fuse; Mains Fuse - Elinchrom D-Lite 4 it Manuel D'utilisation

Masquer les pouces Voir aussi pour D-Lite 4 it:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Before you start !
The D-Lite it (Multivoltage) units are adapted for operation on 90 - 260V/50 - 60Hz. Before con-
necting for the first time, check to make sure that your Modelling Lamp coincides with the voltage.
They must always be connected to an earthed ( grounded) mains supply. All D-Lite it units have a
bayonet mount and locking ring fitting, for fixing all Elinchrom and Prolinca accessories.
The Reflector Bayonet supports Reflectors and Softboxes up to 1.5 kg, e.g. Rotalux 100 x 100 cm .
Mount the unit securely to a suitable stand or support.
Remove the black protective cover. DO NOT operate the unit without first removing the black
protective cover.
Operating instructions
1.Check that the modelling lamp voltage is correct.
2.Check that the mains switch (2) is in the position OFF ("O" position).
3.Insert the mains cable into the MAINS INLET (1) and connect this to a FULLY EARTHED OUTLET
4.Using the mains SWITCH (2), switch the unit ON ("I" position).
5.Connect the synchro cord to its socket (5).
6.Select the power with the touch pad (10)
(B) Protective cover
(26124)
Switch and fuse
Mains supply
Use only the Elinchrom mains cord. Switch off the unit before the mains cord is connected to
the mains plug.

Mains fuse

Standard type 5 x 20 mm, use only tempered fuse 8 AT (code 19022) for D-Lite it
Note: Before exchanging a blown fuse, switch off the unit and remove the mains cable. Open
the little drawer in the mains plug with a screwdriver and replace the fuse with the spare fuse,
which is placed in its support in this drawer. (N.B. Please don't forget to check the correct value
of the fuse!).
Fuse for modelling light
Fast type 5 x 20mm, 2.5 AF
Switch off the unit and replace the blown fuse with a new one of the correct value.
The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore
the flash tube.
(A) Locking ring
English
Handle with
spare fuse
(C) Tilthead with locking
umbrella holder
6

Publicité

loading

Ce manuel est également adapté pour:

D-lite 2 it