Lift off the smoke barrier, pull forward, lower and remove.
NOTE!!
Be careful when replacing the smoke converter plate and smoke chikane

Interruption of operation

Smoke spillage around door
could be due to too low draught in the chimney <12Pa
• check whether the flue or chimney is blocked
• check whether the extraction hood is switched on; if it is, switch it off and open a
window/door in the proximity of the stove for a short while.
Soot on glass
could be caused by
• the firewood is too moist.
Make sure that the stove is heated properly when firing up, prior to closing the door.
Stove is burning too strong
could be caused by:
• leak around the door seal
• chimney draught too large >22 Pa, draught control regulator should be installed.
Remove dirt and dust, and mount
the parts in reverse order.