Télécharger Imprimer la page

Riello Elettronica Cardin SL Série Mode D'emploi page 15

Publicité

Les langues disponibles
  • FR

Les langues disponibles

ELECTRONIC PROGRAMMER
Electronic programmer for a dc motor with an incorporated radio receiver
card, which allows the memorisation of 300 user codes (see "remote con-
trol"). The 'rolling code' type decoder uses 433 MHz series transmitters.
The travel speed is electronically controlled, starting slowly and increasing
in speed; the speed is reduced as it nears the travel limit so as to enable
a controlled smooth stop (if deceleration hasn't been excluded during
programming). Programming is carried out using two buttons and allows
you to configure the system, set the length of the deceleration stage and
set the work and pause times. The intervention of the anticrush/antidrag
sensor during the closing and opening stages causes travel direction inver-
sion (if automatic reclosing has been activated). If activated towards the
end of the movement (almost closed) it will act as a travel limit.
Soft stop
In each blocking manoeuvre (even the one preceding travel direction
inversion) the stopping of the motor is carried with a slight trip stage
(0.4 seconds) in which the gate leaf keeps moving due to inertia and
not by the motor (which is no longer receiving power). Once this brief
stage has ended the gate leaf will be definitely blocked. Conse-
quently when you are positioning the catch which will activated the
travel limit you must bear in mind that there will be a slight delay
between the instant in which the travel limit activates and when the
gate leaf blocks.
ELECTRICAL CONNECTION
• Open the "Standard wiring diagram". To make it easier to follow
the instructions the diagram has been placed on the inside of the last
page of this manual.
ELECTRONIC CARD DESCRIPTION (fig.12)
B1
Signal buzzer "via radio" mode
CN1 Secondary Faston connection 24 Vac logic card power supply
CN2 Secondary Faston connection motor circuit power supply
V0:0 Vac, V1:22 Vac, V2:30 Vac
CN3 Battery Faston connection
D1
Seven segment display
F1
1,6 A delayed action fuse (230 V power supply protection)
F2
1 A rapid action fuse (24 V circuit protection)
F3
10 A rapid action fuse (motor power supply protection)
J1
Enable transmitter memorisation via radio
J2
Radio channel selection
L1
LED power on
L2
LED transmitter code programming
L3
LED manual operation mode
L4
LED inverting photocells activated
L5
LED opening travel limit
L6
LED closing travel limit
L7
LED blocking button activated
L8
LED stop photocell activated
M1
Memory module
P1
Programming button (PROG)
P2
Selection button (SEL)
P3
Transmitter code memorization button (MEMO)
P4
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
LP
Flashing warning lights
LS
Indicator light
FCA
Opening travel limit
FCC
Closing travel limit
FTC-RX Photocell receiver
FTC-Tx
Photocell transmitter
PS
Safety buffer pressure switch
SEL
Selector switch
TB
Blocking button
ANS400 External antenna
Before connecting the appliance make sure that the voltage and fre-
quency rated on the data plate conform to those of the mains supply.
A multiple pole trip switch with a least 3 mm between the contacts
must be installed between the unit and the mains supply.
• Do not use cables with aluminium conductors; do not solder
the ends of cables which are to be inserted into the binding posts;
use cables which are marked T min 85°C and are resistant to
atmospheric agents.
• The terminal wires must be positioned in such a way that both
the wire and the insulating sheath are tightly fastened (a plastic
jubilee clip is sufficient). If possible use the supplied cable clamp.
ELECTRICAL CONNECTION 230 Vac
• Connect the control and security device
wires.
• Run the 230 Vac mains power supply
through the trip switch "TS" and the
through the rubber cable clamp "PS"
to the terminal board:
- connect the live to post 23
- connect the earth to post 28
- connect the neutral to post 24
Terminal board connection
1-2
Common for all inputs and outputs.
3
24 Vac
(1)
in output, powering external devices
4-5
Common for all inputs and outputs
LP 24 Vac 10 W
(1)
6
in output warning lights.
7-8
Second radio channel output:
max. load ac/dc 60 VA/24 W
-
-
max. voltage 30 Vac/dc
9
TD (contact normally open) dynamic button input "Open-Close"
10
TB (contact N.C.) Blocking button input (The opening of this contact
interrupts the cycle until a new movement command is given).
11
Common for all inputs and outputs.
12
FCC (normally closed contact) closing travel limit switch.
13
FCA (normally closed contact) opening travel limit switch.
FTCI (normally closed contact) Safety and control devices in input
14
(photocells invert the travel direction when an obstruction is detected).
The opening of this contact will provoke travel direction inversion
during closure due to the cutting in of the safety device.
15
FTCS (normally closed contact) Safety and control devices in input
(stop photoelectric cells). The opening of this contact will block all
movement, until the obstruction has been removed, due to the safety
device cutting in, the gate will then continue moving until it reaches
a travel limit (only in the automatic mode).
16
TC (contact normally open) Closing button in input
TA (contact normally open) Opening button in input
17
TAL (contact normally open) limited opening button
18
Indicator light 24 Vac 3 W
19-20
230 Vac in output powering the toroidal transformer
21-22
23-24
Power supply 230 Vac
25-26
230 Vac 40 W Courtesy light in output
27
Programmer earth wire
28
Motor earth output
29
Outer conductor for radio receiver antenna
30
Inner conductor for radio receiver antenna (if an external antenna is
fitted use a coaxial type cable RG58 with an impedance of 50Ω).
Note
If the device is fitted with batteries the output voltage during blackouts
(1)
will be in direct current. It follows therefore that you must make sure that the
external devices connected to these outputs can work of direct current.
ALL UNUSED NC CONTACTS MUST BE JUMPED
Switch on the power and make sure that the red indicator LEDS are in the
following condition:
- L1
Power on LED
- L2
Transmitter code programming LED
- L3
Manual operation mode LED
- L4
Safety LED for the inverting photoelectric cells "FTCI"
- L5
Opening direction travel limit LED "FCA"
- L6
Closing direction travel limit LED "FCC"
- L7
Safety LED for the blocking button "TB"
- L8
Safety LED for the stop photoelectric cells "FTCS"
*The LEDs are "ON" if the relative security device is inactive (depends on the
position of the gate).
Check that the activation of the safety devices switches the corresponding LEDS off.
If the red power on LED doesn't light up check the condition of the fuses
and the power cable connection between binding posts "23" and "24" (fig. 12).
If one or more of the safety LEDS do not light up check the contacts of the
relative safety devices and check that the unused safety device contacts have
been bridged.
15
230 Vac
L
N
TS
28
27
L
N
trf 230V~
on
off
off
on
on*
on*
on
on

Publicité