IMPORTANT REMARKS
READ THE FOLLOWING REMARKS CAREFULLY BEFORE PROCEEDING WITH THE INSTALLATION. PAY PARTICU-
LAR ATTENTION TO ALL THE PARAGRAPHS MARKED WITH THE SYMBOL
INSTRUCTIONS COULD COMPROMISE THE CORRECT WORKING ORDER OF THE SYSTEM AND CREATE DANGER
SITUATIONS FOR THE USERS OF THE SYSTEM.
• These instructions are aimed at professionally qualified "INSTALLERS OF
ELECTRICAL EQUIPMENT" and must respect the local standards and
regulations in force. All materials used must be approved and must suit the
environment in which the installation is situated.
• All maintenance operations must be carried out by professionally qualified
technicians. Before carrying out any cleaning or maintenance operations
make sure the power is disconnected at the mains.
• This appliance must be used exclusively for the purpose for which it has been
made "i.e. for the automation of sliding gates". The unit 101/SL4024M9 is
suitable for driving sliding gates with weights of up to 400 Kg.
This product and all its relative components has been designed and manu-
factured by Cardin Elettronica who have verified that the product conforms
in every aspect to the safety standards in force.
Any non authorised modifications are to be considered improper and there-
fore dangerous. The manufacturer accepts no liability for situations arising
from the use of an electrical installation which does not conform to the local
standards and regulations in force and in particular when the earthing circuit
is not efficient.
• After having installed the device (and before powering up the program-
mer) proceed as follows: release the gate and move it manually (with the
motor in neutral), checking that it moves smoothly and has no unusual
points of resistance and that the travel limits activate correctly, then block
the motor again.
• The gate can be operated in the manual mode and moved in the closing
direction using the "SEL" button. The gate will move while the button is
pressed and stop when it is released.
• The programmer is fitted with an electrical input monitoring system, which
is used to block the motor in emergency conditions; however this system
is not active during the following stages:
- during the first 5 seconds of an opening stage starting from completely
closed;
- during the first 2.5 seconds of all other movement stages.
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
Do not therefore attempt to physically block the gate during these stages,
otherwise you may risk blowing the motor circuit protection fuse "F3".
Caution! The presence of the electrical input monitoring system
does not exclude the need to install photoelectric cells or other
safety devices which are foreseen by the local standards and
regulations in force.
Caution! The geared motor unit has been assembled in the fac-
tory to be fitted to the left side of the gate. Read the paragraph
"instructions for positioning the unit".
Caution! If you need to check the status of the fuse "F2", discon-
nect the power supply to the programmer; reconnect it only after
having re-inserted the fuse.
OVERALL DIMENSIONS
IMPORTANT REMARKS
150
140
45
. NOT READING THESE IMPORTANT
IMPORTANT SAFETY INSTRUCTIONS
It is the responsibility of the installer to make sure that the following public safety
conditions are satisfied:
1) Ensure that the gate operating installation is far enough away from the main road
to eliminate possible traffic disruptions and that the size of the gate, the distance
from the road and the work cycle speed can in no way interfere, causing possible
traffic hazards.
2) The motor must be installed on the inside of the property and not on the public
side of the gate. The gate must not open onto a public area.
3) The gate operator is designed for use on gates through which vehicles are passing.
Pedestrians should use a separate entrance.
4) The minimum controls which may be installed are OPEN-STOP-CLOSE, these
controls must be installed at a height between 1,5 and 1,8 m and in a location not
accessible to children. Controls installed externally must be protected by a safety
device inhibiting unauthorised use.
5) The gate must be in full view when it is operating therefore controls must be situ-
ated in a position where the operator can see the gate at all times.
6) At least two warning signs (similar to the example) should be placed,
where they can be easily seen by the public, in the area of the system
of automatic operation. One inside the property and one on the public
side of the installation. These signs must be indelible and not hidden by
any objects. Make sure that the end-user is aware that children and/or
pets must not be allowed to play within the area of a gate installation.
7) A correct earth connection is fundamental in order to guarantee the
electrical safety of the machine
8) Before carrying out any cleaning or maintenance operations make sure the power
is disconnected at the mains, the motor power cables are disconnected and the
batteries have been disconnected.
9) If you have any questions about the safety of the gate operating system, do not
install the operator. Contact your dealer for assistance.
TECHNICAL DESCRIPTION
• Motor powered with a maximum voltage of 38 Vdc.
- A two-piece shell made of die cast aluminium enclosing the reduction unit and a
pair of steel gears, lubricated with permanently fluid grease.
- The reduction unit stator is made of die cast aluminium and contains a never
ending screw and a helicoidal crown wheel made of thermoplastic lubricated with
permanently fluid grease.
- Irreversible reduction system with a key operated manual release mechanism.
- The incorporated electronic programmer contains the power stage, the logic con-
trol and the radio receiver decoding module. The power supply is routed to the
electronics card via a separate transformer which is housed in the same container
and is connected to the card by Faston clips.
- Mechanical travel limits in a watertight container; Cover in shockproof plastic.
Accessories
106/CRENY
- Rack (20 mm x 30 mm) in glass fibre with upper
fastening slits (1 m).
106/CRENY1 - Rack (20 mm x 30 mm) in glass fibre with lower
fastening slits (1 m).
106/SLOAC
- Rack in galvanised steel (22 mm x 22 mm)
2 m to be welded.
106/SLOAC2
- Rack in galvanised steel (12 mm x 30 mm)
1 m with fastening slits.
950/XLBS
- Contact safety edge available in lengths of:
1,5 and 3,0 m maximum height 70 mm.
173
116
12
IMPORTANT REMARKS
290
WARNING
AUTOMATIC OPENING
KEEP CLEAR
CHILDREN OR PETS MUST NOT
BE ALLOWED TO PLAY ON OR
NEAR THE INSTALLATION
3