1.2 The "Remote on/off" function (Ph 12/600 and Ph xx/800
models only)
The Ph 12/600, Ph 24/800 and Ph 48/800 models are equipped with
"Remote on/off" terminals for connection to an external on/off switch.
The two wires of the external switch must be connected to these
terminals as indicated below. When operating the unit by a remote
switch, the slide switch on the frontpanel must be moved to the right
(factory setting is left).
control by local switch
The local on/off switch on the frontpanel always overrides the remote
switch. So in order to use the remote switch, the local on/off switch
must be in the 'on' or 'economy' position.
MAKE SURE THAT WHEN
INSTALLING THE REMOTE SWITCH,
THE BATTERY IS NOT CONNECTED
YET.
CAUTION
victron energy
control by remote switch
max. 50 meters
manual
remote spst
switch
7