1. INSTALLATION

1.1 Location of the inverter

1
Ceiling mounting
(inverted).
2. Base mounting.
3
Vertical wall mounting,
fan at bottom.
4
Vertical wall mounting,
fan on top.
5
Horizontal wall mounting. OK
For best operating results, the inverter should be placed on a flat
surface. To ensure a trouble free operation of the inverter, it must be
used in locations that meet the following requirements:
a) Avoid any contact with water. Do not expose the inverter to rain or
moisture.
b) Do not place the unit in direct sunlight. Ambient air temperature
should be between 0 °C and 40 °C (humidity < 95% non
condensing). Note that in extreme situations the inverter's case
temperature can exceed 70 °C.
c) Do not obstruct the airflow around the inverter. Leave at least 10
centimetres clearance around the inverter. When the inverter is
running too hot, it will shut down. When the inverter has reached a
safe temperature level the unit will automatically restart again.
6
Not recommended
OK
OK (beware of small objects falling
through the ventilation openings on
top).
Not recommended