IF THE INVERTER SWITCHES TO AN
'ERROR MODE' (SEE CHAPTER 2.1)
DUE TO AN OVERLOAD OR SHORT
CIRCUIT, THE INVERTER WILL
AUTOMATICALLY RESTART AFTER
ABOUT 18 SECONDS.
In case of an over-temperature error, the
inverter will automatically restart after it has
reached an acceptable temperature. Just before
WARNING
the inverter restarts, it will warn you with a
short beep (except Phxx/220 models).
NEVER TOUCH THE AC
CONNECTIONS WHEN THE INVERTER
IS STILL RUNNING IN AN ERROR
MODE!
THE BUILT IN LARGE ELECTROLYTIC
CAPACITORS CAN HOLD SIGNIFICANT
DC VOLTAGE WHEN THE BATTERIES
ARE DISCONNECTED.
To avoid sparks or short inverter operation, it is
advisable to switch on the inverter for 10
WARNING
seconds after battery disconnection, before you
transport the inverter.