SANITSON PREMIUM
INSTRUCTIONS DE MONTAGE ET DE MISE EN SERVICE
FRANCAIS
DES MODULES DE RELEVAGE PROFESSIONNEL
INSTALLATION AND STARTING INSTRUCTIONS FOR
ENGLISH
PROFESSIONAL SEWAGE PUMPING MODULES
ISTRUZIONI DI MONTAGGIO E DI MESSA IN SERVIZIO
ITALIANO
DELLE STAZIONI DI SOLLEVAMENTO PROFESSIONALE
N.M.S.
STOCK N° 2.525.917/Ed.1/06.06

Publicité

loading

Sommaire des Matières pour salmson SANITSON PREMIUM

  • Page 1 SANITSON PREMIUM INSTRUCTIONS DE MONTAGE ET DE MISE EN SERVICE FRANCAIS DES MODULES DE RELEVAGE PROFESSIONNEL INSTALLATION AND STARTING INSTRUCTIONS FOR ENGLISH PROFESSIONAL SEWAGE PUMPING MODULES ISTRUZIONI DI MONTAGGIO E DI MESSA IN SERVIZIO ITALIANO DELLE STAZIONI DI SOLLEVAMENTO PROFESSIONALE N.M.S.
  • Page 4 FIG. 1 SANITSON PREMIUM 200-40 - 1 MINI-SDL204...
  • Page 5 FIG. 2 SANITSON PREMIUM 400-40 - 2 MINI-SDL204...
  • Page 6 FIG. 3 SANITSON PREMIUM 200-50 - 1 SVO205/206...
  • Page 7 FIG. 4 SANITSON PREMIUM 400-50 - 2 SVO205/206...
  • Page 8 FIG. 8 WILO DrainControl M1/EM WILO DrainControl M1/EM FIG. 9...
  • Page 9 La station de relevage SANITSON PREMIUM est destinée au relevage des eaux des immeubles et terrains situés au-dessous du réseau Gamme d’égout. À cet effet, la SANITSON PREMIUM peut être aussi bien ins- Volume de la cuve tallée à l’intérieur du bâtiment qu’à l’extérieur.
  • Page 10 4. PRODUITS ET ACCESSOIRES vants. La station de relevage SANITSON PREMIUM est une installation à une 2.1 Symboles des consignes du manuel pompe ou deux pompes qui peut être utilisée dans deux types d’ins- tallation : Risque potentiel mettant en danger la sécurité...
  • Page 11 FRANCAIS 5. INSTALLATION - MONTAGE dans le sens d’écoulement du fluide. - Positionner le tuyau d’arrivée dans le réservoir, dans la zone prévue 5.1 Installation à l’intérieur du bâtiment (Voir FIG. 6 - ci-dessous), en prenant garde à positionner celui-ci de Lors de l’installation des stations de relevage, il convient d’observer telle manière que l’arrivée des effluents ne viennent pas perturber la réglementation en vigueur et de manière générale, les données...
  • Page 12 FRANCAIS Ø 75. Pour cela, scier l’extrémité de 30 mm, éliminer les bavures et Une seule extension peut être installée. ATTENTION ! le matériau résiduel. Utiliser un tuyau à manchon en plastique tra- En cas d’installation de plusieurs extensions et ditionnel comme tube guide-fils et le faire glisser sur les raccords donc d’une profondeur d’encastrement supérieure à...
  • Page 13 - Nettoyer l’intérieur du réservoir. - Il est recommandé de laisser le SAV de SALMSON se charger de la - Contrôler visuellement l’installation électrique. mise en service. - Contrôler visuellement l’état du réservoir.
  • Page 14 1.2.1 Description 1.1 Application SANITSON PREMIUM-200-40 The SANITSON PREMIUM lifting station is designed for lifting water from buildings and ground below the sewer system. The SANITSON PRE- Range MIUM may therefore be installed either indoors or outdoors. Volume of the tank...
  • Page 15 4.2.1 ”Professional” model 2.3 Dangers run if the instructions are not followed - The SANITSON PREMIUM; a station fitted with a tank , and in parti- Not obeying the safety instructions may endanger both staff and the cular including a stainless piping, a flange of fixing with integrated system.
  • Page 16 ENGLISH 5. INSTALLATION – MOUNTING system. Choose a position where the inlet pipe enters the tank ver- tically. Allow for a minimum distance of 50 mm between the ope- 5.1 Indoor installation ning's outer edge and the adjacent edges/stiffeners ! When lifting stations are installed, the current regulations, and more generally, the information given in standard EN12056, ”Indoor gravity Orifice for connecting a...
  • Page 17 ENGLISH 5.4 Mounting the pump FIG. 12 5.7 Positioning the level detection system IPAE 0-1 mCE (4-20mA) - Secure the APS inside Ø 32 PVC pipe in support at the bottom of the tank. FIG. 10 Flange piping of discharge integrated. FIG.
  • Page 18 - Check that the pumps and ducts have been fitted in a secure and leaktight way. If it is not possible to correct the fault, an approved fitter or Salmson's ASS team should be contacted. - Connect to the mains supply.
  • Page 19 • Frequenza : 50 Hz A seconda del tipo, le stazioni di recupero SANITSON Premium sono conformi alle norme 12050-1 o 12050-2 (vedi tabella 2). • Raccordo di arrivo degli effluenti : DN100 In caso d'inosservanza dell'utilizzo dei componenti citate sotto (per •...
  • Page 20 4. PRODOTTI E ACCESSORI successivi paragrafi. La stazione di recupero SANITSON PREMIUM è dotata di una o due 2.1 Simboli delle istruzioni del manuale pompe e può essere utilizzata in due tipi d'impianti :...
  • Page 21 ITALIANO 5. INSTALLAZIONE - MONTAGGIO - Selezionare la posizione in modo che il tubo di arrivo entri vertical- mente nel serbatoio. Rispettare una distanza minima di 50 mm tra il 5.1 Installazione all'interno dell'edificio bordo esterno dell'apertura e i bordi/le nervature contigue ! Quando si installano delle stazioni di recupero, è...
  • Page 22 ITALIANO come tubo guidafili, e farlo scivolare sui raccordi segati, quindi far Può essere installata una sola estensione. ATTENZIONE passare i fili (vedi FIG. 9). In caso d'installazione di più estensioni e quindi di una profondità d'incastro superiore a 1,3 m, la sicurezza statica 5.4 Montaggio della pompa dell'installazione non è...
  • Page 23 - Prima di mettere in servizio la pompa, aprire la valvola situata nel Se non è possibile rimediare al guasto, rivolgersi ad un installatore condotto di mandata. autorizzato o al Servizio Clientela di Salmson. - Verificare che il montaggio della o delle pompe e dei condotti sia fisso e impermeabile.
  • Page 24 53, BOULEVARD DE LA REPUBLIQUE - ESPACE LUMIÈRE - F-78403 CHATOU CEDEX TEL. : +33 (0) 1 30 09 81 81 - FAX : +33 (0) 1 30 09 81 01 www.salmson.com POMPES SALMSON - SAS AU CAPITAL DE 16.775.000 SIREN 313 986 838 RCS VERSAILLES - APE 291C...