ELECTRIC BOX

The electric switch board is made according to Electromagnetic Compatibility Norms (2004/108 CE) and Electrical
Safety Rules for the Low Tension Appliances (2006/95 CE).
Inside the electric box there are the following components:
6. General disconnector with fuses;
7. Phase Sequenze relay;
8. Compressor Contactors;
9. Relays;
10. Terminals for remote control.

MICROPROCESSORS

The microprocessors check all the function of the machine like: General functioning, automatic defrost system,
alarms and set point of the humidty and temperature (only for TCR Version).

VERSIONS

AVAILABLE MODELS AND THEIR ACCESSORIES

HOT GASDEFROST VERSION (S):

the air contact surface and, consequently, the performance; if the frost accumulation is excessive, it can seriously
damage the whole system. All units are provided with Desfrost System. The defrosting is controlled by the
electronic system in combination with a thermostat, whose bulb is installed inside the evaporator.
The standard versions have their defrost simply throughly the periodic stop of the compressor and fan ventilation,
using the heat of the environment itself. In the versions with Hot Gas Defrost System, fan turns off and compressor
continues to work in order to melt the ice in the evaporator.
During the defrosting time the DEFROST light is ON.

HEATERS VERSION (+4kW) :

TEMPERATURE CONTROL VERSION (TCR):

external remote condenser that is connected with the dehumidifier. The use of the remote condenser allows the
control of the temperature and humidity at the same time, operating in cooling or dehumidifying mode. In order to
use both functions it's necessary to have a thermostat and an hygrostat.
The regulation can be ON/OFF or modulating.

HOT WATER COIL VERSION:

hot water at 70°C is pumped in, the coil gives about 10-12kW depending on the model installed (inlet air at the hot
water coil 35°C) of heating power with a loss of pressure of about 20 kPa.
PUMP VERSION:
in this machines is installed a predisposition for the connection of a lift pump for the relaunch of
the moisture.
The machine is provided with a socket for the pump's connection between pump and machine.
the frost which covers the battery, obtrsucts the passage of the air, reduces
these units are provided with electrical heaters to increase outlet air temperature.
the units for the control temperature version are equipped with
in these machines an hot water coil is installed, after the condenser. If in the coild