Water filter system for deionization

2.2 Technical specifications

2.2.1 Physical data - REFILL 50plus, REFILL 100plus

Operating pressure .......................6 bar at 20°C, 3 bar at 50°C
Operating / water temperature ......5 - 50°C
Ambient temperature when
filter is in operation .......................4 - 30°C
Storage temperature new filter ......-20 - 50°C
Recommended nominal flow ........2 l/min – REFILL 50 plus
....................................................5 l/min – REFILL 100 plus
Inlet connection............................3/4" G
Outlet connection .........................3/4" G
Assembly .....................................Connection fitting - wall, polyglass cartridge hanging
Operating situation .......................vertical

2.2.2 Physical data - REFILL 150plus

Operating pressure .......................6 bar at 20°C, 3 bar at 50°C
Betriebs- / Wassertemperatur .......5 - 50°C
Ambient temperature when
filter is in operation .......................4 - 30°C
Storage temperature new filter ......-20 - 50°C
Recommended nominal flow ........7 l/min – REFILL 150 plus
Inlet connection............................3/4" G
Outlet connection .........................3/4" G
Assembly .....................................Connection fitting - wall, polyglass cartrdige floor standing
Operating situation .......................vertical

2.2.3 Physical data - REFILL-VA

Operating pressure .......................10 bar at 20°C, 6 bar at 50°C
Betriebs- / Wassertemperatur .......5 - 50°C
Ambient temperature when
filter is in operation .......................4 - 30°C
Storage temperature new filter ......-20 - 50°C
Recommended nominal flow ........9 l/min – REFILL-VA.14
....................................................17 l/min – REFILL-VA.26
....................................................26 l/min – REFILL-VA.40
Inlet connection............................3/4" G
Outlet connection .........................3/4" G
Assembly .....................................Connection fitting - wall, Stainless steel cartridge floor standing
Operating situation .......................vertical

2.2.4 Electrical data MINIgarde capacity indicator

The MINIgarde conductivity indicator for capacity monitoring is battery operated.
Power supply: integrated battery ...1.5 V
Page 23