1.6 Specific safety and work instructions

The REFILL plus water filter system is only suitable for treating water for technical applications. The
treated water is not suitable for human consumption.
The treated water may only be used if the filter is operated within its capacity limit (<10 μS/cm
conductivity to be measured at the outflow of the cartridge). When operating above the specified
capacity limit, the water can have an acidic pH value, which can lead to damage in the downstream
pipeline network.
When starting up and if the water filter system is not used for a long time, the filter should be flushed
with a quantity of water corresponding to twice the filter volume before use. To avoid microbiological
contamination, the filter should be rinsed and the ion exchange resin should be replaced once a year.
Please note the safety data sheets for the ion exchange resin.
Only water of tap water quality may be used as feed water for the REFILL plus water filter system. The
water filter system is only suitable for cold water applications within the water inlet temperature range
specified in the technical data. Under no circumstances may microbiologically contaminated water or
water of unknown quality be used without adequate disinfection.
The filter system is not resistant to highly concentrated cleaning agents.
The filter system must not be opened or dismantled during operation. The filter cartridge must not be
opened without relieving pressure first.
Depending on the version, the polyglass container is designed for a service life of 10 years. An
exchange should take place after this time.
Protect the water filter system from sunlight and mechanical damage. Do not use near heat sources
and open flames. A safety valve must be installed in front of the inlet connection in accordance with
the European standard DIN EN 1717.
If the water pressure on the inlet side is greater than 6 bar, a pressure reducer must be installed in
front of the water filter system.
To avoid contamination from particles, a filter <50 μm should be installed in front of the filter system.
All parts must be installed in accordance with the country-specific guidelines.
REFILL plus must be operated within the specified ambient temperatures.
Caution in the event of frost: After commissioning, storage and transport of water-filled systems
below 4°C should be avoided. Frost can destroy the water filter system.